Hansgrohe Focus 31718 Serie Instrucciones De Montaje página 16

Important! The fitting must be installed, flushed
and tested after the valid norms!
Assembly
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing
washer in position on the basin / bidet.
3.
Slide the fixation piece including the washer
over the threaded pins and tighten the nuts.
4.
Connect the supply pipes to the isolation
valves; cold right - hot left.
The hot and cold supplies must be of equal
pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Technical Data
This mixer series-produced with
waterdimmer® (flow limiter).
Rate of flow with waterdimmer:
Rate of flow without waterdimmer:
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Test certificate
DVGW
31718000
31714000
31722000
4
7 l/min 0,3 MPa
13 l/min 0,3 MPa
max.1 MPa
0,1 – 0,5
1,6 MPa
max. 80° C
65° C
P-IX
SVGW
P-IX
9625(IA
P-IX
9625(IA
P-IX
9625(IA
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
If the continuous water heater causes any
problems or there is not enough flow of water,
the waterdimmer® (6a) located behind the
aerator must be removed.
To adjust the hot water limiter on single lever
mixers, please see page _1b.
No adjustment is necessary when using a
continuous flow water heater.
Spare parts see page 3
1
handle
2
screw cover
3
flange
4
nut
5
cartridge cpl.
6
aerator
7
fixing set
8
connection hose
9
connection hose
ACS
NF
X
X
X
31791000
96338000
96656000
96680000
92730000
13085000
96016000
97206000
96321000
WRAS
KIWA
X
X
loading

Este manual también es adecuado para:

Focus 31714000Focus 31722000