17
Technical Information
Interconnections
When a data is indicated between two quotes ('...') it means that the indicated
NOTE
data is the correspond-ing ASCII character
Table 4
Data type
Logic (L)
Numeric (N)
Alphanumeric (A)
The addressed SLAVE will respond with an ANSWER whose structure
depends from the MESSAGE type.
228/268
<STX> (Start of transmission) = 0x02
<ADDR> (Unit address) = 0x80 (for RS 232) <ADDR> (Unit
address) = 0x80 + device number (0 to 31) (for RS 485)
<WIN> (Window) = a string of 3 numeric character indicating the
window number (from '000' to '999'); for the meaning of each
window see the relevant paragraph.
<COM> (Command) = 0x30 to read the window, 0x31 to write into
the window
<DATA> = an alphanumeric ASCII string with the data to be
written into the window. In case of a reading command this field
is not present. The field length is variable according to the data
type as per the following table:
<ETX> (End of transmission) = 0x03
<CRC> = XOR of all characters subsequent to <STX> and
including the <ETX> terminator. The value is hexadecimal coded
and indicated by two ASCII character.
Field length
Valid characters
1
'0' = off
'1' = on
6
'-', '.', '0' . . . '9' right
justified with '0'
10
from blank to '_' (ASCII)
TV 303 User Manual / 87-901-019-01