17
Technical Information
Interconnections
It is a 15-pins D type connector; the available signals are detailed in
the table, the following paragraphs describe the signal characteristics
and use.
Table 2
Pin N.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Signal Description
START/STOP: input signal to start or stop the pump. With the
supplied cover connector the START/STOP (+) signal is connected to
the +24 Vdc pin and the START/STOP (-) signal to the GROUND pin:
in this condition the pump automatically starts as soon as the
controller recognises the input supply ("Plug & Pump").
218/268
Signal characteristics and use
Signal name
Start/Stop (+)
Start/Stop (-)
Spare
Programmable set point (-)
Spare
Spare
Spare
Spare
+ 24 Vdc
Spare
Programmable set point (+)
Spare
Spare
Spare
• Ground
TV 303 User Manual / 87-901-019-01
In/Output
In
In
In
In
In
In
In
In
Out
Out
Out
Out
Out