PRODUCT SPECIFICATIONS
SPECIFICATIONS
Showerhead Max. Flow Rate: 1.8 GPM (6.8 LPM) at 80 PSI
ASME A112.18.1/CSA B125
Chrome finish
ASSEMBLY INSTRUCTIONS
1.
Turn off water at the supply valve
under the sink or at the main water
supply, disconnect the supply line,
and remove old faucet.
Verify that the hole sizes and positions
in the wall are correct.
IMPORTANT: Complete valve replacement is required for this tub/shower unit.
An access hole must be cut with enough room to install the new tub/shower
valves inside the wall. Professional installation is recommended.
CAUTION: Do not use PEX tubing for pipe from the valve to the tub spout.
2.
Recommended component locations
The dimension for the valve center line
to the finished wall is 1-7/8" min. to
2-7/8" max. Recommended dimension
is 2-3/8".
FIG. 2A - Shower and / or spout outlet
hole, 1-1/4" diameter.
FIG. 2B - Cut or leave a 1-3/8" to 2"
diameter hole (recommended 1-3/4")
for the cold water inlet side (the right
side) and for the hot water inlet side
(the left side). The center to center
distance between the cold water inlet
and hot is 8".
CAUTION: Allow at least 2" between
tub outlet and tub rim.
3.
When attaching threaded fittings, use
pipe tape or pipe thread compound
according to manufacturer's
instructions. Thread iron supply pipe
(3A) into tailpiece (3B). Assemble
tailpiece into valve body (3C).
Tighten with a wrench.
4.
Connect shower and tub outlet pipes
(4A) to valve body (4B), not included,
to the ends of both pipes. Securely
fasten to wall framing or other solid
support.
Turn on water supply inlet valves to
check for leaks.
www.homewerksww.com
1
2
Fig. 2A
Fig. 2B
3
3C
3B
3A
4
4A
4B
4A
SPECIFICATIONS
Washerless cartridge
Total weight of item: 2.972 lbs.
5.
PRESSURE TESTING:
Install a 1/2" iron pipe plug (5A),
not included, on both shower (5B)
and tub outlets (5C). Turn hot and
cold valve stem to full position, then
turn the diverter stem to the tub and
shower position. Check all connec-
tions for leaks.
NOTE:
To close COLD valve turn clockwise.
To open turn counter-clockwise.
To close HOT valve turn clockwise.
To open turn counter-clockwise.
6.
TUB AND SHOWER
COMBINATIONS:
To flush foreign material from the
lines, slowly remove pipe plugs and
turn on hot and cold water supply
lines and allow water to flow from
shower and tub outlets.
7.
SHOWER HEAD
INSTALLATION
Insert the long end of the shower
arm (1) through the flange (2),
and wrap thread sealant tape
(not included) around the long end
of the shower arm threads (1) in a
clockwise direction, as shown. Install
the long end of the shower arm (1)
into the pipe elbow inside the wall.
Attach the showerhead (3) to the
shower arm (1). Carefully tighten the
shower arm (1) and showerhead (3).
Do not overtighten.
8.
TUB SPOUT
INSTALLATION
Thread spout onto threaded
connection clockwise until the
spout becomes flush with the
finished wall.
2
5
5B
5A
CLOSE
CLOSE
HOTC
OPEN
OPEN
5C
5A
6
7
2
1
3
8
OLD