12V POWER SUPPLY
LOGIC WITH MICROPROCESSOR
ELECTRONIC ADJUSTMENT OF MOTOR TORQUE
END OF MANEUVER MOTOR DECELERATION
DOOR OPENING AND CLOSING DELAYS
WORK AND PAUSE TIME SELF-LEARNING FUNCTION
LED DISPLAY OF INPUT STATUSES
12V INPUT PROTECTION WITH FUSE
12V OUTPUT PROTECTION WITH FUSE
BUILT-IN BATTERY CHARGER CIRCUIT
CONNECTIONS TO THE TERMINAL BOARD
1-2
OPTIONAL: 12 VDC POWER SUPPLY supplementary voltages INPUT
+ Terminal 1, - Terminal 2. Contacts may only be used with the stabilizer card.
3-4
12 VDC 6Ah DRY BATTERY input,
The battery powers the panel for 24 h in the standby mode and approx. 20 minutes if the motor is
working
+ Terminal 3, - Terminal 4.
5-6
12 V OUTPUT 12 VDC outlet, max. 20 W.
For power supply to RECEIVERS and PHOTOCELLS, etc
Protected by a 3,15A fuse (5x20).
+ Terminal 5, - Terminal 6.
7-8
M1 motor output 12 VDC max. 50 W.
Connect the motor with the electric lock. Delayed action during closing (this delay can be adjusted
with dip-switches 7A and 8A). Protected by a 12 Ah fuse.
9-10
M2 motor outlet 12 VDC max. 50 W.
Connect the motor without the electric lock. Delayed action during opening. (Fixed delay).
Protected by a 12 Ah fuse.
11-14
12 VDC output for FLASHING LIGHT, max. 20 W. + Terminal 11, -Terminal 14 (Common=14).
12-14
INDICATOR LIGHT OUTPUT 12 VDC max. 15 W.
This lights up at the beginning of the opening phase until the gate is totally closed.
+ Terminal 12, -Terminal 14 (Common=14).
13-14
ELECTRIC LOCK OUTPUT 12 VDC max. 15 W.
This is active for 1 second before and 3 seconds after the close delay door (M1) starts opening.
DIP 2B can be used to select the courtesy light which remains on for approx. 3 minutes after the
maneuver has terminated. + Terminal 13, - Terminal 14 (Common=14).
15-17
PEDESTRIAN pushbutton input (Normally Open contact); this does exactly the same job as the
OPEN/CLOSE pushbutton; DIP 1A is used to control this function. (Common=17).
If the card is configured for 2 motors the pedestrian impulse completely opens the M1 motor door.
If it is configured for one motor the pedestrian open function can be programmed as preferred.
(approx. 30 maneuvers).