10. Switchable pulse frequency, 8 kHz / 16 kHz; default setting: 16 kHz
8 kHz: pulse frequency for two-pole motors, e.g. inrunners.
16 kHz: pulse frequency for motors with more than two poles, e.g. outrunners.
11. Low-voltage cut-off mode; default setting: full cut-off
Soft: reduced power
Hard: complete cut-off
Programming
1. Switch the transmitter on and move the throttle stick fully forward. Connect the flight battery
to the speed controller (ESC).
2. After three to four seconds you will hear the first audio sequence of programming mode. If
you leave the throttle stick at the full-throttle position, the controller generates various audio
sequences indicating the user-variable parameters - see table below.
3. The audio sequence for each individual parameter is repeated four times. If you wish to change
a particular parameter, move the throttle stick to the Stop position within the period of the four
repetitions. After this the controller emits an audio sequence according to the set battery type
(see "Using the speed controller for the first time").
Note: every time you change a parameter, disconnect the speed controller from the battery for
about two seconds; this causes the unit to store the new setting.
You can only change one parameter during each programming process.
Audio sequences in programming mode
Audio sequences
1
Full-throttle / Stop position
--, --, --, --
2
Brake
-*, -*, -*, -*
3
Battery type
~, ~, ~, ~
~~, ~~, ~~, ~~
4
Low-voltage cut-off
*--, *--, *--, *--
*---, *---, *---, *---
*----, *----, *----, *----
5
Reset to default settings
-, -, -, -
6
Timing
-, -, -, -
--, --, --, --
---, ---, ---, ---
7
Start-up / Power-on mode
vv, vv, vv, vv
v, v, v, v
vvv, vvv, vvv, vvv
Operating Instructions
Arcus Sport Power Set
8
9
10
11
Safety notes
- Keep to the correct sequence when switching on: always switch the transmitter on first, fol-
lowed by the receiver. Reverse the sequence when switching off.
- Do not exceed the values stated in the Specification.
- Take care to maintain correct polarity in all wiring.
- It is essential to avoid short-circuits.
- Install and protect the speed controller in such a way that it cannot come into contact with
grease, oil or water.
- Provide adequate air circulation for cooling.
- Keep well clear of the rotational plane of the propeller when the battery is connected - injury ha-
zard.
Controller functions
Guarantee
Naturally we guarantee this speed controller for the statutory period of 24 months. If you believe
you have a valid claim under guarantee, please contact your dealer in the first instance, as he is
Brake on / off
responsible for processing guarantee claims. During the guarantee period we will correct any ope-
rating deficiencies, production defects and material faults which arise, at no charge to you. We will
NiMH / NC
not entertain any claims beyond these terms, e.g. consequent damage.
LiPo
The unit must be returned to us carriage-paid; it will also be returned to you carriage-paid. We will
not accept goods sent to us without pre-paid carriage.
Low: 2.8 V / 50%
We accept no liability for transit damage and the loss of your shipment; we therefore recommend
Medium : 3.0 V / 60%
that you take out suitable insurance to cover these risks.
High: 3.2 V / 60%
Send the unit to the Service Centre responsible for the country in which you live.
Reset
The following conditions must be fulfilled if we are to process your guarantee claim:
• Send proof of purchase (till receipt) with your shipment.
Automatic (7 - 30°)
• The unit must have been operated in accordance with the operating instructions.
Low (7 - 22°)
• The unit must have been operated with the recommended power sources and genuine robbe
High (23 - 30°)
accessories.
• The unit must not exhibit damage due to damp, unauthorised intervention, reverse polarity, over-
Ultra-soft
load conditions or mechanical damage.
Soft
• Please include a concise description of the fault or defect, as this will help us identify the pro-
Normal
blem.
Helicopter mode
-*-, -*-, -*-, -*-
-**-, -**-, -**-, -**-
-***-, -***-, -***-, -***-
Motor direction
W, W, W, W
Pulse frequency
//, //, //, //
\\, \\, \\, \\
Low-voltage / Cut-off mode
---", ---", ---", ---"
"---, "---, "---, "---
Speed governor mode off
Soft-start, 5 sec. delay
Soft-start, 15 sec. delay
Right / Left
8 kHz
16 kHz
Reduced power
Full cut-off