Maintenance
Cleaning the urinal trap
It is essential to clean the urinal trap
regularly in order to keep the urinal flush
control functioning correctly. Hard water
and urine will cause urine scale deposits to
build up. These deposits may impair the
function of the sensors in the urinal trap and
clog the urinal trap.
Cleaning recommendations:
• use standard WC cleaning agents for
deposits from hard water.
• also remove any deposits in the trap
bend and in the adapter leading to the
discharge pipe. demount the urinal
ceramic to clean the trap.
• if the deposits are heavy, replace the
urinal trap. → Contact a skilled person.
To clean the urinal ceramic and the urinal
trap, the flush actuation can be suppressed
for a few minutes using a Geberit app.
Setting the flush time
The flush time can be adjusted to suit the
user's needs using a Geberit app.
9007206862832523-1 © 04-2021
970.151.00.0(00)
Replace the batteries
Flush actuation no longer takes place if the
batteries are dead. The state of battery
charge is indicated by the LED on the urinal
flush control or else can be checked using a
Geberit app.
Refer to the following figure sequence
page 206 while following the instructions.
Prerequisite
2 replacement batteries (alkaline
batteries, 1.5 V, AA) are available.
1
Demount the urinal ceramic.
2
Disconnect the cables to the urinal
trap and the solenoid valve.
3
Remove the urinal flush control.
4
Open the battery compartment and
remove the dead batteries.
5
Insert new batteries and close the
battery compartment.
6
Insert the urinal flush control.
7
Connect the cables to the urinal trap
and the solenoid valve.
8
Install the urinal ceramic.
9
Check the flush actuation with 0.5 l
water or with a Geberit app.