Information Codes - Samsung WF511AB Serie Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INFORMATION CODES

The washer may display information codes to help you better understand what is occurring with your
washer.
CODE SYMBOL MEANING
Downloaded from
www.Manualslib.com
WF511ABR-03010A_EN.indd Sec7:35
WF511ABR-03010A_EN.indd Sec7:35
Unbalanced load prevented your
dc
washer from spinning.
Door is unlocked when washer is
dL
running.
Door is open when washer is
dS
running.
Your washer failed to lock the
FL
door.
Water temperature control
problem.
Hr
(Heater control problem)
Your washer has tried to fi ll, but
LE
has not reached the proper water
level.
The door will not unlock.
LO
Your washer is not draining.
It can also mean that the unit
senses a small clog while draining.
nd
Your washer has tried to fi ll but
was unsuccessful.
nF
Check if the hot water supply
hose is connected.
The hot/cold water hose
nF1
connection is not correct.
manuals search engine
SOLUTION
Redistribute the load, press the Start/Pause
button.
Press the Power button to turn off your washer,
then restart the cycle. If the code reappears, call
for service.
Close the door tightly and restart the cycle.
If the code reappears, call for service.
Close the door tightly and restart the cycle.
If the code reappears, call for service.
Call for service.
Call for service.
Make sure the door is fi rmly closed.
Press the Power button to turn off your washer,
then turn it on again. If the code reappears, call
for service.
Clean the drain fi lter. Then, clean the
debris fi lter (See page 26).
If you are in the middle of a wash you can try this
fi rst:
1. Turn off the unit for 10 seconds and then turn
it on again.
2. Select the Spin Only cycle (See page 19).
3. Press the Start/Pause to drain the water.
If it still does not drain, call for service.
Make sure the water faucets are open all the
way. Check for kinked hoses.
Check the inlet screens on the fi ll hoses.
If you use a Flood Safety Device, then please
remove the device and connect the water hoses
directly to the unit.
You must connect the hot water supply hose
because hot water is supplied by the Auto
Temperature Control (A.T.C.) function if the
temperature of the cold water is lower than 59°F.
Please connect the hot/cold water hose
connection correctly.
troubleshooting _35
2011-01-18
2011-01-18
4:15:50
4:15:50

Capítulos

Tabla de contenido
loading

Tabla de contenido