Technibel MPAFI3A Instrucciones De Instalación

Acondicionador de aire split system

Enlaces rápidos

DECLARATION OF CONFORMITY
This product is marked
– Low voltage no. 2006/95/EC (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 +
A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 +
A15:2011).
– Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
– RoHS2 no.2011/65/EU.
– Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
– Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation
and/or operating instructions.
í Cooling Maximum conditions
Outdoor temperature :
Room temperature :
í Cooling Minimum conditions
Outdoor temperature :
Room temperature :
Tools required for installation (not supplied)
1.Standard screwdriver
2.Phillips head screwdriver
3.Knife or wire stripper
4.Tape measure
5.Level
6.Sabre saw or key hole saw
7.Hacksaw
8. Core bits ø 8
INSTALLATION INSTRUCTIONS
as it satisfies Directives:
OPERATING LIMITS
43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
19.Hammer
10.Drill
11. Tube cutter
12.Tube flaring tool
13.Torque wrench
14.Adjustable wrench
15.Reamer (for reburring)
16.Hex. key
37.4255.106.04
- Split system air conditioner -
í Heating Maximum conditions
Outdoor temperature :
Room temperature :
í Heating Minimum conditions
Outdoor temperature :
Room temperature :
Model Combinations:
SEE CATALOGUE
Power Supply:
220 - 240 V ~ 50 Hz
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas with
a global warming potential (GWP) of 2087.50. Do not
release R410A into the atmosphere.
01/2017
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
EG
I
F
D
E
Tabla de contenido
loading

Resumen de contenidos para Technibel MPAFI3A

  • Página 1 INSTALLATION INSTRUCTIONS - Split system air conditioner - DECLARATION OF CONFORMITY This product is marked as it satisfies Directives: – Low voltage no. 2006/95/EC (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Página 2: Special Precautions

    IMPORTANT! • Ground the unit following local electrical codes. • The Yellow/Green wire cannot be used for any connection Please read before installation different from the ground connection. • Connect all wiring tightly. Loose wiring may cause This air conditioning system meets strict safety and operating overheating at connection points and a possible fire standards.
  • Página 3 Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with ● foamed polyethylene (min. thickness 8mm). MODEL NARROW TUBE LARGE TUBE OUTER DIAMETER MIN. THICKNESS OUTER DIAMETER MIN. THICKNESS MPAFI3A 6,35 mm 0,8 mm 9,52 mm 0,8 mm 6,35 mm 0,8 mm 0,8 mm MPAFI3B 12,7 mm PVC pipe for condensate drain pipe (ø...
  • Página 5 ISTRUZIONI DI INSTALLAZIONE - Condizionatore d’aria Split System - DICHIARAZIONE DI CONFORMITÀ Questo prodotto è marcato in quanto conforme alle Direttive: – Bassa Tensione n. 2006/95/CE (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Página 6 IMPORTANTE! • Eseguire la messa a terra dell’unità secondo le norme elettriche locali. Leggere prima di iniziare l’installazione • Il conduttore giallo/verde non può essere utilizzato per collegamenti diversi dalla messa a terra. Questo sistema di condizionamento deve seguire rigidi •...
  • Página 7 ● spessore min. 8 mm. MODELLO TUBO PICCOLO TUBO GRANDE DIAMETRO ESTERNO SPESSORE MINIMO DIAMETRO ESTERNO SPESSORE MINIMO MPAFI3A 6,35 mm 0,8 mm 9,52 mm 0,8 mm 6,35 mm 0,8 mm 0,8 mm MPAFI3B 12,7 mm Tubo in PVC per scarico condensa (ø int. 18 mm) di lunghezza sufficiente a convogliare la condensa a uno scarico ●...
  • Página 9: Declaration De Conformité

    NOTICE D’INSTALLATION - Climatiseur split - DECLARATION DE CONFORMITÉ Ce produit est marqué puisque il est conforme aux Directives: – Basse Tension n° 2006/95/CE (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Página 10: Veuillez Lire Ce Qui Suit Avant De Commencer

    IMPORTANT! • Effectuez la mise à la terre de l'appareil en respectant les réglementations électriques locales. Veuillez lire ce qui suit avant de commencer • Le câble jaune/vert ne peut en aucun cas être utilisé pour Ce système de conditionnement de l'air répond à des toute autre connexion que celle de la mise à...
  • Página 11 ● mousse de polyéthylène avec épaisseur min. de 8mm. MODELE PETIT TUBE GROS TUBE DIAMETRE EXTERIEUR EPAISSEUR MIN. DIAMETRE EXTERIEUR EPAISSEUR MIN. MPAFI3A 6,35 mm 0,8 mm 9,52 mm 0,8 mm 6,35 mm 0,8 mm 0,8 mm MPAFI3B 12,7 mm Tube en PVC pour sortie du condensat (Ø...
  • Página 13: Konformitätserklärung

    INSTALLATIONSANLEITUNGEN - Zweirohrsystem-Klimaanlage - KONFORMITÄTSERKLÄRUNG Dieses Produkt ist mit -Zeichen gekennzeichnet, weil es den folgenden Richtlinien entspricht: – Niederspannungsrichtilinie 2006/95/EG (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Página 14 WICHTIG! Tod verursachen. • Erden Sie das Gerät gemäß den örtlich zutreffenden Bitte vor Arbeitsbeginn lesen Vorschriften. Diese Klimaanlage entspricht strengen Sicherheits- und • Das Gelbe/Grüne Kabel ist für die ausschließliche Betriebsnormen. Verwendung als Erdleitung. • Verbinden Sie Kabel fest miteinander. Lockere Für den Installateur oder Bediener dieser Anlage ist es Verbindungen können...
  • Página 15 Polyethylenisolierung (r Isolierung min. 8mm). MODELL ENGES ROHR WEITES ROHR AUßENDURCHMESSER MIN. DICKE AUßENDURCHMESSER MIN. DICKE MPAFI3A 6,35 mm 0,8 mm 9,52 mm 0,8 mm 6,35 mm 0,8 mm 0,8 mm MPAFI3B 12,7 mm PVC-Rohr für Kondenswasser-Auslaß (Innen ø 18mm). Es soll lang genug sein, um das Kondenswasser zu einer ●...
  • Página 17: Acondicionador De Aire Split System

    INSTRUCCIONES DE INSTALACION - Acondicionador de aire Split System - DECLARACION DE CONFORMIDAD Este Producto está marcado porque responde a las Directivas: – Baja Tensión n° 2006/95/CE (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Página 18: Precauciones Especiales

    ¡IMPORTANTE! • Realizar la puesta a tierra de la unidad siguiendo las normas eléctricas locales. Leer antes de empezar la instalación • El conductor amarillo/verde no se puede utilizar para conexiones que no sean la de tierra. Este sistema de acondicionamiento cumple medidas rígidas •...
  • Página 19: Material Adicional Para La Instalacion (No Suministrado)

    ● conexión entre las unidades. MODELO TUBO PEQUEÑO TUBO GRANDE DIAMETRO EXTERIOR ESPESOR MINIMO DIAMETRO EXTERIOR ESPESOR MINIMO MPAFI3A 6,35 mm 0,8 mm 9,52 mm 0,8 mm 6,35 mm 0,8 mm 0,8 mm MPAFI3B 12,7 mm Tubo de PVC para descarga de condensación (ø int. 18mm) de longitud suficiente como para transportar el líquido de ●...
  • Página 20 INDOOR UNIT • UNITÀ INTERNA • UNITE INTERIEURE • INNENEINHEIT • UNIDAD INTERIOR Minimum operation and maintenance area. 100-150 Area minima di esercizio e manutenzione. Surface minimum de fonctionnement et d’entretien. Raumbedarf des Gerätes . 2000 Area mínima de funcionamiento y manutención. 1110 Remove and discard the set screw on the rear panel.
  • Página 21 MPAF13A MPAF13B Hintere Verrohrung. Nivellieren und die zu schneidenden Tubing connections from the rear. Check the horizontal Löcher für die Verrohrung und die Schrauben zeichnen: position with the level, mark the holes to be made for the die Mittellinie der Löcher für die Verrohrung muß mit tubes and the screws: the center line of the holes for der Mittellinie der Löcher der unteren Schrauben the tubes must be aligned with the center line of the...
  • Página 22 Use the screws to fix the rear panel to the wall. Make sure the panel is flush against the wall. Any space between the wall and unit will cause noise and vibration. Usando le viti, fissare il pannello posteriore al muro. Assicurarsi che l’unità...
  • Página 23 Running the multipolar power supply wire and the connecting wire from indoor to outdoor unit (see table for wires’ size). Stendere il cavo multipolare di alimentazione e il cavo di collegamento tra le due unità (vedere tabella per la sezione dei fili). Passer le câble électrique multipolaire d’alimentation et le câble de raccordement entre les deux unités (voir tableau pour la section des fils).
  • Página 24 RIGHT REAR TUBING Insert refrigerant tubes and drain hose of the unit into the hole in the wall then hang up the unit on the rear panel previously fixed on the wall. USCITA TUBAZIONI LATO DESTRO POSTERIORE Inserire le tubazioni e il tubo di scarico condensa nel foro praticato nel muro.
  • Página 25 Push lightly to fix the unit to the rear panel. Applicare una leggera pressione per agganciare la struttura al pannello posteriore. Pousser légèrement pour accrocher la structure au panneau arrière. Das Gitter leicht drücken, um es an die Rückwand zu hängen. Presionar ligeramente para enganchar la estructura en el panel trasero.
  • Página 26 Install the condensate drain to the outside with a positive slope, form a trap at the end if necessary. Convogliare la condensa verso l'esterno assicurando una buona pendenza. Sifonare se necessario. Diriger les condensats vers l'extérieur, en assurant une bonne pente. Faire un siphon, si nécessaire.
  • Página 27: Longitud, Seccion De Cables Y Fusibles De Accion Retardada

    LENGTH, SIZE WIRES AND DELAYED FUSE • LUNGHEZZA, SEZIONE CAVI E FUSIBILI RITARDATI • LONGUEUR, SECTION CABLES ET FUSIBLES RETARDES • KABEL-LÄNGE UND QUERSCHNITT UND TRÄGE SICHERUNGEN • LONGITUD, SECCION DE CABLES Y FUSIBLES DE ACCION RETARDADA SEE INSTALLATION INSTRUCTIONS OF OUTDOOR UNIT V.
  • Página 28: Posizione Del Telecomando

    Cable de alimentación A : Cable eléctrico multipolar; la sección y la longitud del cable eléctrico aconsejado están indicadas dentro de la tabla “Datos eléctricos” (Unidad exterior). Cable de conexión B (BLINDADO): Cable eléctrico bipolar blindado; la sección y la longitud del cable eléctrico aconsejado están indicadas dentro de la tabla “Datos eléctricos”...
  • Página 29 WALL-MOUNTED POSITION • Momentarily place the remote control unit in the desired mounting position. • Verify that the remote control unit can operate from this position. • Fix the support at the wall with two screws and hang the remote control unit. POSIZIONE A PARETE •...
  • Página 30 PUMP DOWN (See Installation Instruction of Outdoor Unit) Das bedeutet: das Kühlmittel in die Außeneinheit ohne Pump down means collecting all refrigerant gas in the Gas-Verlust zurückzugewinnen. Man benutzt es, wenn system back into the outdoor unit without losing gas. das Klimagerät in eine neue Position gestellt werden Pump down is used when the unit is to be moved of muß...
  • Página 31 OUTDOOR/INDOOR UNIT REFRIGERANT CIRCUIT ADDRESS Indoor units that are part of a multisplit system must be properly configured to be able to communicate with the outdoor unit over different channels (Indoor A, Indoor B, etc...) of the communication bus. Each indoor unit address must correspond to the physical connection of the indoor unit to the outdoor unit refrigerant circuit, i.e.: Refrigerant Circuit A <-->...
  • Página 32 (2) ADDRESS SETTING THROUGH REMOTE CONTROLLER (UP TO 8 INDOOR UNITS) Set the remote controller as shown in the table. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C...
  • Página 33 (3) AUTOMATIC ADDRESSING PROCEDURE System requirements: Outdoor unit must have a recent firmware version that supports the automatic addressing procedure. Indoor units must have a recent firmware version that supports the automatic addressing procedure Dip-switch for communication address setting on the indoor unit (SW1) must be left to the factory default state, i.e. to the OFF position.
  • Página 34: Indirizzo Circuito Refrigerante Unita' Esterna/Interna

    INDIRIZZO CIRCUITO REFRIGERANTE UNITA’ ESTERNA/INTERNA Le unità interne che fanno parte di un sistema multisplit devono essere opportunamente collegate in modo da comunicare con l’unità esterna su diversi canali (Indoor A, Indoor B, etc...) del bus di comunicazione. Ogni indirizzo dell’unità interna deve corrispondere a un collegamento fisico dell’unità interna con il circuito refrigerante dell’unità...
  • Página 35 (2) IMPOSTAZIONE INDIRIZZI TRAMITE TELECOMANDO (FINO A 8 UNITA’ INTERNE) Impostare il telecomando come indicato in tabella. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C flap...
  • Página 36 (3) PROCEDURA DI INDIRIZZAMENTO AUTOMATICO Requisiti di sistema: L’unità esterna deve avere una versione firmware recente che supporti la procedura di indirizzamento automatico. Le unità interne devono avere una versione firmware recente che supporti la procedura di indirizzamento automatico. I microinterruttori per l’impostazione dell’indirizzo di comunicazione sull’unità interna (SW1) devono essere lasciati nello stato di fabbrica, cioè...
  • Página 37 ADRESSE DU CIRCUIT DE REFRIGERATION UNITE EXTERIEURE/INTERIEURE Les unités intérieures qui font partie d'un système multisplit doivent être configurés correctement pour communiquer avec l'unité extérieure sur plusieurs canaux (unité intérieure A, unité intérieure B, etc ...) du bus de communication. Chaque adresse de l'unité...
  • Página 38 (2) REGLAGE DES ADRESSES AVEC LA TELECOMMANDE (JUSQU’A 8 UNITES INTERIEURES) Régler la télécommande comme indiqué dans le tableau. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C flap...
  • Página 39 (3) PROCEDURE D’ADRESSAGE AUTOMATIQUE Exigences du système: L'unité extérieure doit avoir une version récente du firmware qui prend en charge la procédure d'adressage automatique. Les unités intérieures doivent avoir une version récente du firmware qui prend en charge la procédure d'adressage automatique.
  • Página 40 AUSSEN/INNENEINHEIT-KÜHLROHRE ADRESSE Inneneinheiten, die Teil eines Multisplit-System sind, müssen korrekt konfiguriert sein, um mit der Außeneinheit über verschiedene Kanäle des Kommunikationsbusses zu kommunizieren (Inneneinheit A, Inneneinheit B, etc..). Jedes Inneneinheit-Adresse muß auf die physikalische Verbindung der Inneneinheit zur Außeneinheit Kältemittelkreislauf entsprechen, d.h.: Kältemittelkreislauf A <-->...
  • Página 41 (2) ADRESSEN-EINSTELLUNG MIT DER FERNBEDIENUNG (BIS ZU 8 INNENEINHEITEN) Stellen Sie die Fernbedienung ein, wie in der Tabelle gezeigt ist. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C...
  • Página 42 (3) AUTOMATISCHE ADRESSIERUNG System Anforderungen: Die Außeneinheit muß eine aktuelle Firmware-Version haben, die die automatische Adressierung unterstützt. Die Inneneinheiten müssen eine aktuelle Firmware-Version haben, die die automatische Adressierung unterstützen. Die Schalter für die Kommunikation Adresseinstellung auf der Inneneinheit (SW1) müssen auf die Werkseinstellung belassen werden, d.h.
  • Página 43 DIRECCION DEL CIRCUITO DE REFRIGERACIÓN UNIDAD EXTERIOR/INTERIOR Las unidades interiores que son parte de un sistema multisplit deben estar configurados correctamente para poder comunicar con la unidad exterior a través de diferentes canales (unidad interior A, unidad interior B, etc ...) del bus de comunicación.
  • Página 44: Regulacion De Las Direcciones Con El Mando A Distancia (Hasta 8 Unidades Interiores)

    (2) REGULACION DE LAS DIRECCIONES CON EL MANDO A DISTANCIA (HASTA 8 UNIDADES INTERIORES) Regular el mando a distancia como indicado en la tabla. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C...
  • Página 45: Procedimiento De Direccionamiento Automático

    (3) PROCEDIMIENTO DE DIRECCIONAMIENTO AUTOMÁTICO Requisitos del sistema: La unidad exterior debe tener una versión reciente de firmware que soporta el procedimiento de direccionamiento automático. Las unidades interiores deben tener una versión reciente de firmware que soporta el procedimiento de direccionamiento automático.
  • Página 46 REFRIGERANT CIRCUIT CHECK • CONTROLLO CIRCUITO REFRIGERANTE • CONTROLE DU CIRCUIT DE REFRIGERATION • NACHPRÜFUNG DER KÜHLROHRE • COMPROBACIÓN DEL CIRCUITO DE REFRIGERACIÓN 1. Power ON the system. 2. Set the remote controller of unit A as following (units B, C and D must be OFF): -Mode: COOLING -Filter: ON -Set-point: 32°C...
  • Página 47 MATCH BETWEEN REMOTE CONTROLLER AND INDOOR UNIT • ABBINAMENTO TRA TELECOMANDO E UNITA’ INTERNA • COMBINAISON ENTRE TELECOMMANDE ET UNITE INTERIEURE • KOMBINATION ZWISCHEN FERNBEDIENUNG UND INNENEINHEIT • COMBINACION ENTRE MANDO A DISTANCIA Y UNIDAD INTERIOR Disconnect the power of indoor unit. ●...
  • Página 48 Set SW3 (PCB) as shown in the table. Impostare SW3 (PCB) come indicato in tabella. Régler SW3 (PCB) comme indiqué dans le tableau. Stellen Sie SW3 (PCB) ein, wie in der Tabelle gezeigt ist. Regular SW3 (PCB) como indicado en la tabla. REMOTE CONTROL UNIT INDOOR UNIT TELECOMANDO...
  • Página 52 Z.I. Route départementale 28 01600 Reyrieux France Tél. 33 4 74 00 92 92 - Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Este manual también es adecuado para:

Mpafi3b

Tabla de contenido