Application
Secure Controller as the central
controller for managing access rights
in private buildings and commercial
properties.
Performance features:
• 2 RS485 interfaces
• 4 doors per controller
• Protocol OSDP / Vario Bus
• Max. 500,000 users
• Max. 16 modules per controller
• Max. 64 controllers can be net­
worked
• Log for 1,000,000 events
• Programming via web interface
• Wizard for easy commissioning
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Scope of supply
• Secure Control SC 600­0
• This product information
For download
• Commissioning instruction
Terminal assignment
LAN
Network
NO,
Relay
COM,
NC
EXIT
Input (Door release)
GND
common reference
point
Inputs
CONTACT Input (Door status)
D­, D+
Data lines
OUT+,
Supply of OSDP
GND
modules
Vin, GND
Supply voltage
14–30 V DC
Vout, GND
Output voltage
12 V DC
4
OUT­1
Controllable
transistor output 1
OUT­2
Controllable
transistor output 2
OUT­3
Controllable
transistor output 3
Mounting
1 When mounting directly on the
wall, secure the base plate with
4 screws. Observe the horizontal
installation position. The maximum
installation height is 2 metres.
2 Attach the housing to the base
plate and secure with a screw.
Conductor material
• When supplying the SC 600-... via
PoE in accordance with 802.3af
(POE class 3), a shielded CAT 6a
cable must be used.
• A shielded and twisted­pair
cable must be used to connect the
modules. The shield must be con­
nected to the metal housing of the
SC 600-...
Installation
3 Connect in accordance with the
terminal diagram.
Remarks
a) A maximum of 8 modules can be
connected per RS485 line.
b) Alternative supply via the
NG 706-30/33-... line rectifier.
c) The housing's PE earthing connec­
tion must be connected.
Specifications
Operating voltage: PoE in accord­
ance with 802.3af (PoE class 3),
14–30 V DC
Operating current: max. 115 mA
Contact type: 4 changeover switches
30 V DC, 10 A
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Dimensions (mm) W x H x D:
140 x 215 x 50
Français
Application
Secure Controller en tant qu'unité
de contrôle centrale pour la gestion
des autorisations d'accès dans les
résidences privées et les bâtiments
industriels.
Caractéristiques fonctionnelles :
• 2 interfaces RS485
• 4 portes par contrôleur
• Protocole OSDP / bus Vario
• 500 000 utilisateurs max.
• 16 modules max. par contrôleur
• 64 contrôleurs max. utilisables en
réseau
• Fichier Log pour 1 000 000 évé­
nements
• Programmation via interface web
• Assistant pour une mise en service
facile
Tension électrique
L'installation, le montage et l'entre­
tien d'appareils électriques ne
doivent être réalisés que par un spé­
cialiste en électricité.
Etendue de la fourniture
• Secure Control SC 600-0
• La présente information produit
Vers le téléchargement
• Notice de mise en service
Implantation des bornes
LAN
Réseau
NO,
Relais
COM,
NC
EXIT
Entrée (Gâche)
GND
Point de référence
commun
Entrées
CONTACT Entrée (Statut de la
porte)
D­, D+
Ligne de données
OUT+,
Alimentation des
GND
modules OSDP
loading