Storing The Generating Set; Troubleshooting; Specifications - SDMO ineo 3000 Manual De Utilización Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

8. Storing the generating set

In case of prolonged non-usage of the generating set, carry out storage operations in accordance with the guidelines given below.
Drain all the fuel from the fuel tank into a suitable container.
Run the engine till it stops due to lack of fuel.
Renew the engine oil.
Remove the spark plug (fig. E – no. 2) and pour around 15ml of engine oil into the cylinder through the spark plug opening.
Refit the spark plug.
Pull the recoil starter handle 3 to 4 times (fig. A – no. 7) to completely drain-out the carburetor and distribute the oil inside the
cylinder.
Clean the exterior of the generating set and cover it with the protection cover in order to protect it from dust.
Store the generating set in a clean and dry spot.

9. Troubleshooting

Problems
Load connected to the generating set while starting.
The oil level is too low.
The engine does
Insufficient fuel level
not start
Fuel feed system blocked or elusive
Air filter blocked
Ventilation openings blocked
The engine
The oil level is too low.
stops
Overload indicator (fig. A – no. 11) turned on: overload.
Defective device power supply cord.
No electric
Defective electrical socket.
current
Defective alternator.

10. Specifications

Model
Type of Engine
Maximum output / Rated output
Direct Current
Alternating Current
Socket type
Circuit-breaker
Oil cut-out
Battery
Acoustic pressure level at 1 m in dB(A)
Weight in kg (without fuel)
Dimensions L x w x h in cm
Recommended oil
Oil sump capacity in litres
Recommended fuel
Fuel tank capacity in litres
Spark plug
● : standard
Probable cause
o : optional
Disconnect the load
Check the oil level and top up if necessary.
Fill-up fuel (see § Filling with fuel)
Check, repair or replace.*
Clean the air filter
Clean the suction and discharge guards
Check the oil level and top up if necessary.
Eliminate the overload and wait for 30sec before
restarting.
Change the cord.
Check, repair or replace.*
Check, repair or replace.*
* Operation(s) to be entrusted to one of our agents.
2 x 2P+T - 10/16A - 230V
CHAMPION : RN9YC / NGK :BPR6ES
X : not possible
Possible solutions
NEO 3000
OLYMP ES 128-1
2600 W / 2100 W
12V-5A
230V-9.2A
X
73 dB(A)
24
59 x 30 x 55
SAE 15W40
0.55
Unleaded petrol
4.3

Hide quick links:

Tabla de contenido
loading

Tabla de contenido