- Table 2 shows recommended suction pipe
sizes and eccentric reductions. To avoid air
pockets eccentric reductions must be installed
upgrade towards the pump.
Pump
1500 r.p.m.
size
Size
øsuct x ødisch
Pipe
50 x 32
65
65 x 40
80
65 x 50
100
80 x 65
125
100 x 80
150
125 x 100
200
150 x 125
250
200 x 150
300
(6) For installations with suction head:
- It is recommended to install a shutoff valve on
the suction pipe to make easy the disassembling
and checking.
20
Nº Description
1 Pump
2 Motor
3 Support
4 Elastic sleeve
5 Check valve
6 Shut-off valve
7 Foot valve
8 Eccentric reduction
Fig.1
3000 r.p.m.
Size
Reduction
Pipe
Reduction
65x50
80
80x50
80x65
100
100x65
100x65
125
125x65
125x80
150
150x80
150x100
200
200x100
200x125
250
250x125
250x150
300
300x150
300x200
----
Table 2
- Suction pipe must be installed with a downward
slope towards the pump to avoid the formation
of air pockets.
6.3 Centering
In case of pump provided with motor the join
between both items is made by using a elastic
coupling (with or without spacer).
The pumps are correctly aligned before being
sold, however, when installing, the common base
must be tilted when adjusting the anchorage
bolts. Thus the common base must be adjusted
by placing metal gages under it and aligning the
pump to leave the coupling clearances within the
limits stated on Fig. 2.
If the purchase is made without the motor and
you intend to connect it when installing, correct
the coupling alignment by inserting a fine spacer
under the motor, adjusting the difference within
the limits set in Fig. 2.
----
Alignment is made by moving the coupling
guard, so it is essential to replace it before
starting up.
The coupling size depends on the power of the
motor coupled to pump. For more information
consult to EBARA.
(ENGLISH)