Installation
Wrap duct tape around the ducting and ring joint to prevent any air
leaks.
Pull the insulation back up over the mylar to the ring and tape this joint.
Run the ducting to the other end, keeping it as straight, smooth, and
taut as possible.
Remove excess ducting.
Use the same connection method at the other end.
8.8
Control Panel Installation
The following guidelines should be followed during the installation of the
control panel:
Mount the control panel within 4.5 m of the electrical box.
Mount the control panel on an inside wall, slightly higher than mid-
height of the cabin, in a location with freely circulating air where it can
best sense average temperature.
Do not mount the control panel
– in direct sunlight,
– near any heat producing appliances
– in a bulkhead where temperatures radiating from behind the panel
– in the supply-air stream
– above or below a supply or return-air grille
Before mounting the control panel, consider the location:
Create a cut out size for the control panel:
64 mm wide by 48 mm high.
Plug one end of the display cable (8-pin RJ-45 connector) into the
display socket (J-2) of the electric box and the other end into the back
of the control panel.
Prior to placement clean the mounting surface with isopropyl alcohol
only (test alcohol on hidden portion of surface first).
Secure the control panel to a bulkhead with the adhesive strips pro-
vided.
22
may affect performance
MCS5, MCS15