Models supplied with a power cord with a plug must be plugged into a power outlet. The water heater can be
EN
disconnected from the mains by unplugging it.
IMPORTANT: The outlet must be connected to a separate circuit provided with a safety mechanism. It must
be grounded.
For models equipped with a power cord without a plug, the appliance must be connected to an individual
electrical circuit of fixed installation, equipped with a safety device with a nominal electrical current of 16A
(20A for power> 3700W). The connection must be constant (without a plug). The electrical circuit must be
equipped with a safety device and with a built-in mechanism that ensures the separation of all the poles in
case of type III overvoltage.
• Brown insulation cable to the phase cable of the electrical installation (L).
• Blue insulation cable to the neutral cable of the electrical installation (N).
• Yellow-green insulation conductor cable, to the protective cable of the electrical installation.

5. OPERATION

When you have performed the instructions described in
section 4 above, you can start using the water heater
(which has an indicator light)
The indicator light is turned on when the water heater
is connected to heat the water. The indicator light turns
off when the water reaches the selected temperature
and indicates that the water heater is not in operation
and is no longer heating water.
Ignition switch with 2 positions
• Position 0 = OFF. The water heater is not active
and does not heat water.
• Position I = ON. The water heater is regulated
automatically by the thermostat positions
Control of the thermostat with 5 positions
• Anti-Frost Position
mode, the water heater switches on when the temperature of the water contained in the water tank
falls below 5ºC. It is suitable in cases of low potential water temperature.
NOTE: In this setting, the water heater maintains a temperature that does not allow the water to freeze. The power
supply for the water heater must be activated and the water heater switched on. The safety valve and the pipes must
be protected against freezing.
In the event that the power supply is interrupted for any reason, there is a danger that the water in the tank will
freeze. Therefore, it is recommended to drain the water from the water heater during long absences.
1
.
3
:
4
.
4
:
: set the thermostat at this point for a minimum level of water heating. In this
Tabla de contenido