STEP 7 Connect the water dispenser line (applicable models only)
CAUTION
• The new hose-sets supplied with the appliance are to be used and that old hose-sets
should not be reused.
• The water line must be connected by a qualified technician.
• The warranty for your refrigerator does not cover the water line installation. The
water line installation will be performed at your own costs unless the installation fee is
included in the retailer's price.
• Samsung takes no responsibility for the water line installation. If water leaks occur,
contact the installer of the water line.
To connect the cold water pipe to the water filtering hose
CAUTION
• Make sure the water filtering hose is connected to a cold, potable water source pipe.
Connecting to the hot water pipe may cause the purifier to malfunction.
A
A
A. Close Main Water pipe
B. No gap
Untitled-6 41
1. Shut off the water supply by closing the
main water valve.
1
2. Locate the cold, potable water pipe (1).
3. Follow the Water Line Installation to
connect to the water pipe.
4. When connection is complete, open the
main water valve and dispense about
3 liters of water. This is to remove
impurities inside the pipe.