ATTENTION!
IMPORTANT INFORMATION FOR
INSTALLERS OF THIS EQUIPMENT!
THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY
TECHNICALLY-QUALIFIED PERSONNEL. FAILURE TO
INSTALL IT IN COMPLIANCE WITH NATIONAL AND LOCAL
ELECTRICAL CODES AND WITH FRANKLIN ELECTRIC
RECOMMENDATIONS MAY RESULT IN ELECTRICAL SHOCK
OR FIRE HAZARD, UNSATISFACTORY PERFORMANCE,
AND EQUIPMENT FAILURE. FRANKLIN ELECTRIC
INSTALLATION INFORMATION IS AVAILABLE FROM PUMP
MANUFACTURERS AND DISTRIBUTORS, AND DIRECTLY
FROM FRANKLIN ELECTRIC. CALL FRANKLIN ELECTRIC
TOLL FREE AT 800-701-7894 FOR INFORMATION. RETAIN
THIS INFORMATION SHEET WITH THE EQUIPMENT FOR
FUTURE REFERENCE.
W A R N I N G
SERIOUS OR FATAL ELECTRICAL SHOCK MAY RESULT
FROM FAILURE TO CONNECT THE MOTOR, CONTROL
ENCLOSURES, METAL PLUMBING, AND ALL OTHER METAL
NEAR THE MOTOR OR CABLE TO THE POWER SUPPLY
GROUND TERMINAL USING WIRE NO SMALLER THAN
MOTOR CABLE WIRES. TO REDUCE RISK OF ELECTRICAL
SHOCK, DISCONNECT POWER BEFORE WORKING ON OR
AROUND THE WATER SYSTEM. DO NOT USE MOTOR IN
SWIMMING AREAS.
2
INSTALLATION RECORDS
It is a good idea to keep an accurate record of your
installation. Be sure to record the data below:
Purchased from:
Date of installation:
Pump model*:
Pump date code*:
Well inside diameter (in/mm):
Depth of well (ft/m):
Depth of water (ft/m):
Pump setting (ft/m):
Drop pipe size:
Wire size (pump to control box):
Wire size (control box to power source):
Horizontal offset (between well & house):
Make of motor*
Amps
HP
Make of control box
HP
Power supply
Volts
Pressure switch limits
Cut-in (PSI)
*This information is on your pump or motor tag. It will help
us identify your pump in case of later inquiries.

TEST RUNNING

If test running pump before installation:
1. Ensure that the power supply corresponds with that
shown on the nameplate of the motor and control box (if
required).
2. Install pump and components appropriate for the test as
shown in Fig. 1.
3. Make sure power supply is turned off and circuit breaker
or disconnect switch is open. Make electrical connections
appropriate to your motor as shown in Figure 2, 3 or 4.
4. On a three-phase motor, use a magnetic starter equipped
with quick-trip, ambient compensated heaters of correct
size for the horsepower of the motor.
Volts
Phase
Volts
HZ
Cut-out (PSI)