INSTALLATION
Note: When the range hood and appliance supplied with energy other than electricity are
simultaneously in operation, the negative pressure in the room must be not exceed 4 Pa (4 x
10 -5 Bar).
Required minimum distance hood to
Ceramic-glass rings/hotplates
Gas cooker
Coal / oil / stove wood firing

Installation Steps

Note: Do not connect the power cable until the installation is complete! Get a second person
to help you with the installation.
1.Saw an opening in the wall cabinet under which the hood is to be fitted. Use the following
dimensions as a guide:
Image 1.
2. Insert the range hood into the cabinet. Please make sure the elastic pins of the both sides
are fixed on the cabinet.
Image 2.
10mm~28mm
65 cm
75 cm
85 cm
elastic pin
Tabla de contenido