Make sure that the item is installed by a competent installer.
Shut off the main water supply.
A licensed electrician should route all electrical wiring.
Disconnect power to the valve before servicing.
Observe all local plumbing, electrical and building codes.
Provide access for servicing the valve and the interface.
Installation must be carried out in accordance with these instructions, and must be conducted
The plumbing installation must comply with the requirements of UK Water regulations/Bye-
company or water undertakers.
This appliance must be earthed. Ensure supplementary bonding complies with the
"Requirements for Electrical Installations". The valve is intended to be permanently connected
Mains connections are exposed when the cover is removed.
Do not install the valve in any location where the temperature may reach temperatures over
40°C (104°F). The valve and its integrated power supply is rated to operate in temperatures
up to 40°C (104°F).
When possible, install the valve prior to installing the interface and install the electrical outlet
prior to installing the valve.
For optimum performance, dedicated water supply lines are recommended.
routed from the number 1 outlet port.
The valve contains plastic and rubber components which could melt.
Do not apply petroleum-based lubricants to the valve components.
Do not use oil-based, non-setting compounds, such as plumbers putty on the threaded
connections.
Flush all pipework prior to installing the valve.
The water supplies to this product must be isolated if the product is not to be used for a long
period of time. If the product or pipework is at the risk of freezing during this period they
should also be drained of water.
DO NOT operate this appliance if it is frozen. Allow the appliance to thaw before using. The