DIAGNOSTIC TROUBLESHOOTING
If the toaster malfunctions, the display will flash an error code E and a number between 1-9, or a letter between A-
E. Below are different error codes and their solutions. For Example If error code is EO1, a failure related to the
lower platen controls has occurred. If error code is E1O a failure related to the upper platen controls has oc-
curred.
Diagnostics
EO1
E1O
EO2
E2O
EO3
E3O
EO4
E4O
E44
EO5
E5O
EO6
E6O
Problem
1. Lower Relay Contacts Shorted.
Lower Platen Overheating.
1. Upper Relay Contacts Shorted.
Upper Platen Overheating.
2. Lower Probe Open.
2. Upper Probe Open
3. Lower Failures 1 And 2 Combined
3. Upper Failures 1 And 2 Combined
4. Lower Platen Underheating.
4. Upper Platen Underheating.
Both Platens Underheating.
2. A maximum of 900 sets of buns can be toasted in 1 hour, anything over
that and the toaster can go into an E44 failure. If this happens discontinue
using the toaster for 3 minutes and the failure will clear. You can then resume
using the toaster again. If None of the above occurs, replace the P. C. Board.
5. Lower Failures 1 And 4 Combined.
5. Upper Failures 1 And 4 Combined.
6. Lower Failures 2 And 4 Combined.
6. Upper Failures 2 And 4 Combined.
Replace Lower Relay.
Replace P. C. Board.
Replace Upper Relay.
Replace P. C. Board.
Replace Lower Probe.
Replace Upper Probe.
Replace Lower Relay.
Check Lower Platen Resistance.
Replace P. C. Board.
Replace Upper Relay
Check Upper Platen Resistance.
Replace P. C. Board.
1.Check For Cool Air Blowing On
9
Solution
Toaster.