Commissioning The Device - ProMed AC-4000 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38

COMMISSIONING THE DEVICE

14
Please check that the scope of delivery is complete before commissioning the device.
Only use original parts!
Note
1. For commissioning, please remove the protective film of the device. Subsequently, remove the front cover
(A) by reaching into the air inlet slots on the left and right with your fingers and pulling the cover off
towards the front.
2. Then remove the two filters (I and J) and the their protective film.
3. Now check that the UV tubular lamp (H) is correctly installed.
4. Then insert the filters into the device again: first the combi filter (I) and then the aluminium pre-filter (J).
When doing so, ensure that the pulling straps at the filters are always pointed towards you. Slide the filters
into the opening until they reach the stop; ensure that you only touch the filters at their edge.
5. Now insert the front cover into the lower guides and latch it in the upper retaining magnets.
6. Then insert the mains plug into a socket. Initially, all light indicators of the display will be illuminated, then
the On/Off button will flash. You can then operate the unit via the remote control or directly at the device.
7. The unit is started by actuating the On/Off button.
The display shows the current settings of the unit and the measuring values (room temperature, humidity
and fine dust content in the air). When a certain function is active, the corresponding button flashes. The
sensor buttons acknowledge every press with a "beep" sound.
DE
Display description (functions)
EN
FR
IT
Button for activating and deactivating the device.
ES
Button for setting the fan speed in 3 levels. (On the remote control I, II, III, circulating)
Button for the timer control; each time the button is pressed increases the runtime by one hour; the
maximum runtime is 9 hours. The device switches off automatically once the set time has expired.
NL
Automatic air purification; the intelligent system controls the filter performance in accordance with
the measured air quality. If the air quality is poor, the indicator is illuminated in red, and the fan
RU
runs at the highest level. In the event of a medium air quality, the indicator is illuminated in yellow,
and the fan runs at medium level. If the air quality is good, the indicator is illuminated in green, and the
fan runs at the lowest level.
PL
Values of the fine dust indicator in the corresponding area:
good
SE
medium
poor
AR
μg/m³
Indicator colour
1 - 70 μg/m³
71 to 200 μg/m³
> 200 μg/m³
green
yellow
red
Tabla de contenido
loading

Tabla de contenido