Exhaust System

IMPORTANT: Keep exhaust duct as short as
possible.
NOTE: Be certain old ducts are cleaned before
installing your new dryer.
For best drying results, recommended maximum length
of exhaust system is shown below.
To prevent backdraft when dryer is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least
12 inches (30.5 cm) above the ground. Larger
clearances may be necessary for installations where
heavy snowfall can occur.

Exhaust Direction

The dryer can be exhausted to the outdoors through the
back, left, right or bottom of the dryer. EXCEPTION:
Gas dryers cannot be vented out the left side
because of the burner housing.
Number of
90° Elbows
0
1
2
3
0
1
2
3
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
504607
Recommended
4"
(10.16 cm)
Maximum length of 4" (10.2 cm) diameter rigid metal duct.
44 feet (13.4 m)
34 feet (10.4 m)
26 feet (7.9 m)
20 feet (6.1 m)
Maximum length of 4" (10.2 cm) diameter flexible metal duct.
24 feet (7.3 m)
20 feet (6.1 m)
16 feet (4.9 m)
12 feet (3.7 m)
Dryer is shipped from factory ready for rear exhaust;
no kits required.
Exhausting the dryer through sides or bottom can be
accomplished by installing a DK1 Sales Accessory
(Directional Exhaust Kit 528P3) available as optional
equipment at extra cost.
528P3 Directional Exhaust Kit
Weather Hood Type
Use only for short run installations
4"
(10.16 cm)
D011IE2D
D328IE0A
2-1/2"
(6.35 cm)
D011IE2E
34 feet (10.4 m)
26 feet (7.9 m)
20 feet (6.1 m)
14 feet (4.3 m)
20 feet (6.1 m)
16 feet (4.9 m)
12 feet (3.7 m)
8 feet (2.4 m)