press
to confirm; the display shows
"Programming / type: ";
continue by entering the code of a new
programming function or press the but-
ton
PROG to exit.
Loading names from PC (code 05)
You can load names directly from your
PC.
Load the names on the PC using a
dedicated software application
(software supplied on demand).
Turn off the push-button panel and the
PC.
Connect the PC serial port to the stereo
jack on the back of the push-button
panel with a cable as shown in the
figure.
PC serial port
1
6
2
7
3
8
4
9
5
TD2100PL
PC
Move the jumpers J6 and J7 on the
back of the push-button panel from 1-2
to 2-3.
Turn on the PC and then the push-
button.
Enter the code 05 and press the button
; the display shows "TD2100PL ----
PC / in progress....0".
Download the names from the PC within
15 seconds; the display shows
"TD2100PL ---- PC / in progress....1",
"TD2100PL ---- PC / in progress....2"
and then the downloaded names.
At the end of download the push-button
deletes the existing names. The first
line of the display shows "waiting" and
the second line shows a status bar to
show the progress of the deletion
operation. At the end the display shows
"Programming / type: ".
Turn off the push-button panel and
then the PC.
Disconnect the cable from the PC and
the push-button panel.
Bring the jumpers J6 and J7 back to
1-2.
Ordering names (code 06)
You can list the names in alphabetical
order (from A to Z).
Press the button
programming mode.
Stereo jack
Enter the code 06 and press the but-
Ø = 2.5mm
ton
; the first line of the display
shows "waiting" and the second line
3
shows a status bar; at the end of the
operation the push-button panel re-
2
turns automatically to the program-
5
ming mode (the display shows "Pro-
gramming / type: " ).
5
Continue by entering the code of a
2
new programming function or press
3
the button
Inserting the external door station
address PE
You can code the external door station
address with codes from 231 to 250.
Press the button
programming mode.
Enter the code 10 and press the but-
ton
; the display shows "ADDRESS
PE".
Dial the coding number for the door
station and press the button
confirm.
Continue by entering the code of a
new programming function or press
the button
Inserting the button address P1
(code 11)
To save an extension number and call it
directly from a button connected between
terminals P1/P1:
press the button
programming mode;
enter the code 11 and press the but-
ton
; the display shows "ADDRESS
P1";
dial the extension number. Extensions
must be coded with numbers from
001 to 200;
PROG to enter the
PROG to exit.
(code 10)
PROG to enter the
to
PROG to exit.
PROG to enter the
press the button
to confirm;
continue by entering the code of a
new programming function or press
the button
PROG to exit.
Operations whit door keeper
exchangers (code 30)
Following settings are necessary if in
the system are installed main and/or
secondary door keeper exchangers.
Press the button
PROG to enter the
programming mode.
Enter the code 30 and press the but-
ton
; the display shows "ADDRESS
PDX".
Enter address 201 if the door station
operates with 1 or more main door
keeper exchangers or address 210 if
the door station operates with 1 or
more secondary door keeper ex-
changers.
Press the button
to confirm.
Press the button PROG to exit the
programming mode.
Return to operation mode
Press the button PROG at the end of
programming; the display shows
"FARFISA / dial the number or press
" or the text you have entered during
programming (see "Personalisation
of display initial text").
15