Switching The Unit On And Off - Renfert Pillo Instrucciones Para El Servicio

Ocultar thumbs Ver también para Pillo:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
5. Operation
5.1 Chisel Installation / Removal
(see Figure 5)
Always disconnect the Renfert de-
flasking chisel from the compressed
air supply before chisel exchange or
replacement. Unplug the connector
from the compressed air supply.
Risk of injury!
The employed chisels are sharp.
• To replace an insert, pull the chisel forwards
and out of the tool retainer.
• Insert the new chisel into the tool retainer.
The chisel must clearly lock into place in the
retainer

5.2 Switching the Unit On and Off

The Renfert deflasking chisel is switched on
and off at the ball valve (Figure 6).
• Switching the Unit On
Turn the ball valve anticlockwise until the
Renfert deflasking chisel starts.
• Switching the Unit Off
Turn the ball valve clockwise to its stop.
5.3 Adjust Chisel Force
The chisel force is adjusted by turning of the
ball valve (Figure 6).
5.4 Breaks / Conclusion of Work
• During short breaks:
Turn off at the ball valve.
• For longer breaks or at the conclusion of
work:
Disconnect the unit from the compressed air
supply.
Pillo only:
Do not loosen the connecting hose
on the Renfert deflasking chisel!
5.5 Operational Notes
When working with the Renfert deflasking
chisel, please note the following safety informa-
tion.
Always work away from yourself.
Always wear eye protection! Working
with brittle materials can generate
splinters.
Always wear a dust mask!
Dust from investment materials can
be hazardous to your health. Always
refer to the MSDS (Material Safety
Data Sheets) provided with the
investment material.
Use a dust extraction unit!
The use of a dust extraction unit
(refer to the accessories list) can
significantly reduce health hazards.
Always wear hearing protection. The
unit's sound level typically lies in the
range of 78 dB(A).
During some tasks, the sound level
can exceed 85 dB(A).
Risk of injury!
Compressed air exiting from the
front of the unit represents an injury
hazard. Never direct the Renfert
deflasking chisel towards your face
or towards other individuals.
When working with the Renfert deflasking chisel
please also ensure that the resulting splinters,
dust or noise do not put others at risk.
In order to avoid health risks (e.g.,
white finger syndrome) resulting
from the effects of vibrations on the
hands and arms, please observe the
maximum exposure times specified
by the relevant regulatory agency.
- 3 -
EN
Tabla de contenido
loading

Este manual también es adecuado para:

Power pillo5022-40005022-5000

Tabla de contenido