5.1.1 Collecting tank
The gas-, odour- and pressure-tight collecting tank is made of
wastewater resistant polyethylene (PE) and has all necessary
ports for the connection of inlet pipes, discharge pipe, venting
pipe and a manually operated diaphragm pump, which is
available as an accessory.
The MD collecting tank has a turnable, eccentric disk in the
back allowing adjustment of the inlet to any height between 180
and 315 mm above the floor. The most common heights are
marked beside the inlet. See section
installation of lifting
station.
Furthermore, the MD collecting tank offers four horizontal inlets in
the sides (2 x DN 100 and 2 x DN 50) and three vertical inlets at
the top of the tank (2 x DN 150 and 1 x DN 50). The centres of the
horizontal inlets are 120 mm (DN 50) and 250 mm (DN 150)
above the floor.
The side and back inlets 180 and 250 mm above the floor are for
direct connection to wall-hung or floor-standing toilet according to
EN 33 and EN 37. Further sanitary appliances can be connected
to the other ports.
The MLD collecting tank offers one vertical inlet, DN 50, at the
top of the tank and one vertical inlet, DN 150, in the stepped part
of the tank.
The tank volume and effective volume (volume between start and
stop) for Multilift MD and MLD lifting stations appear from the
following table:
MD
Inlet level [mm]
Total tank volume [l]
Effective tank volume [l]
MLD
Inlet level [mm]
Total tank volume [l]
Effective tank volume [l]
Setting to the relevant start inlet level must be made during the
start-up phase via the setup menu. See section
The first step after power supply connection is a start-up phase
with level setting.
To minimise sedimentation, the tank bottom is chamfered to lead
the wastewater to the pump.
5.1.2 Pumps
The pump impellers are designed as free-flow vortex impellers,
ensuring almost unchanged performance throughout the entire
life of the pump. See the pump curves in section
12.5 Performance
curves. The stator housing of the motor is
made of cast iron. The pump has a mechanical shaft seal.
See more technical data in section
Single-phase motors are protected by a thermal switch in the
windings and run via a capacitor inside the controller cabinet.
Three-phase motors are protected by a thermal switch in the
windings and an additional thermal circuit breaker in the cabinet
of Multilift MD/MLD22, 24, 32 and 38 to cut out the motor in case
of overload.
If the phase sequence for three-phase pumps is wrong, the
controller will indicate fault and prevent the pump(s) from starting.
For correction of phase sequence, see fig. 14. For direction of
rotation, see section
10.2
Motor.
If the motor is overloaded, it will stop
automatically.
Note
When it has cooled to normal temperature, it will
restart automatically.
8
7.3 Procedure for
180
250
315
130
49
69
86
560
270
190
6.2 Setup
menu.
12. Technical
data.
5.1.3 Shaft seal
The pumps have three shaft seals, the oil chambers in between are
filled for life and therefore require no maintenance.
For replacement in case of service, please see service
instructions.
5.1.4 Motor cable
The motor cable is fitted to the motor via a cable entry.
The enclosure class is IP68. The length of the cable is either 4 m
or 10 m.
Nameplate, motor
96075378 - A
Prod.- No.
19
~
Motor
3
20
50
Hz
U
400
21
P
I
2.8
kW
5.3
1
1/1
23
$
P
2.2
kW
COS
0.77
2
22
IP68
24
25
Made in Germany
26
27
Fig. 4
Nameplate, motor
Pos.
Description
19
Product number and model
20
Number of phases
21
Frequency
22
Input power
23
Shaft power
24
Power factor
25
Enclosure class
26
Production country
27
CE mark
28
Production week and year
29
Operating mode
30
Rated speed
31
Weight
32
Insulation class
33
Rated voltage
34
Rated current
5.1.5 Non return valve
The DN 80 non-return valve includes a drain screw to lift up the
internal flap in order to drain the discharge pipe in case of
maintenance or service. The valve is designed and tested
according to EN12050-4. See fig. 5.
Loosen the lock nut a little before turning the
Note
drain screw.
Fig. 5
Butterfly (double) non-return valve, DN 80
96075389
P. c.
0149 001
28
S3-40%-1min
29
V
1405
-1
n
min
30
A
Weight
24
kg
31
Insul.class
F
32
33
34
loading