Installation
1. Ensure￿your￿product￿comes￿with￿the￿items￿indicated￿on￿page￿4;￿if￿not￿please￿contact
your￿dealer.
2. Feed￿cables￿through￿backplate.
3. Use￿two￿screws￿to￿attach￿backplate￿to￿wall.
4. Use￿two￿screws￿to￿attach￿tamper￿plate￿to￿wall.
5. Connect￿cable￿to￿circuit￿board —￿see￿page￿5.
6. Configure￿reader —￿see￿page￿5.
7. Set￿output￿format —￿see￿page￿6.
8. Snap￿reader￿to￿backplate￿and￿secure￿with￿final￿screw.
9. Apply￿power￿when￿all￿readers￿are￿installed.
Notes
If￿power￿is￿applied￿when￿the￿reader￿is￿not￿properly￿attached￿to￿the￿wall,￿a￿wall
tamper￿condition￿is￿generated.
Do￿not￿distort￿the￿back￿plate￿or￿tamper￿plate￿when￿mounting,￿e.g.￿to￿a￿back￿box,
or￿a￿spurious￿wall￿tamper /￿case￿tamper￿condition￿may￿be￿generated.
Mount￿readers￿>3ft￿/￿1m￿apart,￿e.g.￿on￿either￿side￿of￿the￿door.￿Mounting￿on
metal￿surfaces￿will￿reduce￿the￿reading￿range.
If￿the￿reader￿is￿being￿used￿to￿enter￿credential￿information￿to￿arm￿a￿system,￿the
reader￿must￿be￿located￿within￿3ft￿/￿1m￿of￿the￿panel's￿main￿keypad￿or￿display.
For￿outside￿readers,￿use￿corrosion-resistant￿fixings￿and￿apply￿silicone￿sealant￿to
the￿backplate￿before￿fixing￿to￿the￿wall.
The￿supplied￿MOV￿(Metal￿Oxide￿Varistor,￿Anglia￿Components￿P/N
B72207S250K101)￿should￿be￿fitted￿across￿the￿power￿terminals￿of￿the￿lock￿to
suppress￿back￿EMF.￿Any￿suppression￿diodes￿fitted￿in￿the￿lock /￿lock￿circuit￿must
be￿removed.
Output￿format￿and￿reader￿configuration￿can￿be￿changed￿without￿disconnecting
the￿power￿supply.￿The￿reader￿automatically￿restarts￿with￿the￿new￿configuration.