Beko BCL 90 X Manual De Utilización página 22

Campana extractora
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
Fan Speed button (3):
- From off, press once for low speed (1), twice for medium (2),
and three times for high (3).
- Fan should cycle through speeds low (1), medium (2), and
high (3) continuously.
Delay Off button (4):
- If fan is off, press once and fan will turn on at low speed and
automatically turn off after five (5) minutes.
- If the fan is already on (example high speed) the fan will
change to low speed when the Delay Off Button is pressed
and turn off after five minutes.
- When the Delay Off Function is on, the user can still change
the fan speed by pressing the Fan Speed Button without
interrupting the five minute Delay Off Timer.
- Delay Off Function can be turned off by pressing Delay Off
Function button or Power Button.
Light indicator (5): Light indicator will turn on when lights
are turned on at any light level.
Delay Off indicator (6):
- Delay Off Indicator will light up when Delay Off Function is
activated by pressing the Delay Off Button.
- Delay Off Indicator will turn off after the Delay Off Function
has completed the five minute cycle or if the user presses the
Delay Off Button again or the Power Button (delay off timer
enabled and fan speed changed to 1).
Clean Air indicator (7): Clean Air Indicator is disabled by
default and must be enabled by the user.
- To enable Clean Air Function:
• With hood off, hold the Power Button down for five seconds.
Clean Air Indicator light will illuminate, and the fan will turn on
low speed for 10 minutes. After 10 minutes the fan will turn
off and the 4 hour timer will begin.
• Clean Air Indicator will remain on when Clean Air Function
is enabled, even if fan is not on.
- When Clean Air Function is enabled, every four hours of non
fan usage the fan will automatically turn on at low speed for
10 minutes. After 10 minutes the fan will turn off and the 4
hour timer will reset.
- When the Clean Air Function automatically turns the fan
on the Clean Air Indicator will blink and the Low Speed fan
indicator will illuminate.
- If the user changes the fan speed while the Clean Air Function
is operating, the Clean Air Indicator will stop blinking but will
remain illuminated. When the user manually turns the hood
off the 4 hour timer will reset.
- To disable Clean Air Function:
• With hood off, hold Power Button down for five seconds until
Clean Air Indicator light turns off.
• Note 1: Changing the fan speed and interrupting the Clean
Air Function while it is operating does not disable the Clean Air
Function. Clean Air Function will only be disabled by holding
the Power Button for 5 seconds.
• Note 2: Turning lights on/off does not disable the Clean
Air Function (*clean air function enabled with low fan speed
turned on by clean air function).
Fan Speed indicator (8):
= Low
= Medium
= High
- On speed low, only number 1 indicator will be on.
- On speed medium, 1 and 2 indicator will be on.
- On speed high, 1, 2 and 3 indicators will be on.
- When fan off, no fan speed indicator will be on.