6. TROUBLESHOOTING
Problems
The display that indicates the DMX
address does not turn on
The green LED in the DMX
modulator does not light up
The projectors change colour or
go out for a few moments
If you are unable to solve the problem with these instructions, contact the technical department of IGNIALIGHT.
7. SAFETY WARNINGS
• The persons who are in charge of assembly should have the required qualifications for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
• In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL WIRING. SWIM-
MING POOLS.
• Any operation related to the maintenance or replacement of parts should be performed with the floodlamp
disconnected from the electric power system.
• The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric
components which have been inserted or handled at locations other than its own premises.
Usual causes
Current
is
not
reaching
equipment
Defective DMX signal
Faulty power supply in the
projectors or in the DMX
modulator
5
Solutions
the
Check the mains socket (230 V~ac
of power supply) and the 24V
power line
Check the installation of the DMX
line. Only the line termination of the
last DMX equipment of the DMX
communications bus should be
activated
Check the 24V
DC Power
supply line of the projectors and
the DMX modulator
DC