Manual mode ProMax ClearDrain 7000
The pump remains permanently switched
on if the float switch is set vertically and
the cable points downward.
N O T E
The pump can run dry in manual mode.
• Switch off the pump when the minimum
water level is reached.
• Running the pump dry increases wear.
D
• Move the handle into the horizontal po-
sition and push the cable directly at the
transition to the float switch into the ca-
ble clip such that the float switch is in a
vertical position.
Automatic mode ProMax ClearDrain
11000/14000
The pump switches on when the rising wa-
ter reaches the sensor.
Metal contacts at the bottom of the sensor
strip detect the minimum water level
(switch-off point). When the minimum wa-
ter level is reached, the pump switches off.
E
• Fit the sensor onto the sensor strip in
the desired switch-on position.
Manual mode ProMax ClearDrain
11000/14000
F
The pump is switched on when the sensor
is inserted in the top-most position of the
sensor strip.
Metal contacts at the bottom of the sensor
strip detect the minimum water level (de-
activation point). When the minimum wa-
ter level is reached, the pump switches off
with a brief delay.
• Repeat the process: Reinsert the sen-
sor in the top position of the sensor strip.
Setting the residual water level
The pump can pump the water down to a
depth of 6 mm to 8 mm or down to 1 mm.
G
• Residual water level 6 ... 8 mm: Fit the
spacer ring and secure with the retain-
ing ring (bayonet closure).
• Residual water level down to 1 mm
(shallow extraction): Release the retain-
ing ring (bayonet closure) and remove
the spacer ring.
N O T E
Shallow extraction is only possible in
manual mode.
Installing the pump
H
• Install the pump in a horizontal and sta-
ble position in the water.
• If it needs to be lowered into a well or a
shaft, fasten a rope to the handle. Do
not carry it by the power connection
cable.
• Install the pump such that it does not
take in dirt particles with a size >5 mm,
which would block the intake. Install the
pump in a raised position if necessary.
• ProMax ClearDrain 7000: Ensure that
the float switch can always move freely.
DE
EN
FR
NL
ES
PT
IT
DA
NO
SV
FI
HU
PL
CS
SK
SL
HR
RO
BG
UK
RU
CN
15