GAZ-PROTEC – Gas detector
5.1 S
WITCHING THE DEVICE ON
The central unit and the sensors in your gas detector are fitted with a test
The central unit and the sensors in your gas detector are fitted with a test
button (Fig. 1-A).
Your gas detector is equipped with an On/Off switch to activate / deactivate
By pressing one of its buttons when the system is switched on and initialised,
the system as required.
you can check the working order of each of the components.
If you press the TEST button on the main unit, its red indicator light goes on
If you press the TEST button on the main unit, its red indicator light goes on
Turning the system on:
and the alarm sounds.
To turn the system on, press the button on the main unit (Fig. 1-A)
o
If you press the TEST button on one of the sensors, its red indicator light
If you press the TEST button on one of the sensors, its red indica
for 3 to 4 seconds. It emits a beep; the lights on the unit and on the
goes on and the red indicator light on the main unit goes on at the same time.
goes on and the red indicator light on the main unit goes on at the same time.
sensors go on (green light only on the LPG sensor).
The alarm in the sensor sounds as does the one in the main unit.
The alarm in the sensor sounds as does the one in the main unit.
The system starts its initialization phase. This phase lasts between 1
o
If one of these elements does not work, contact your dealer.
and 3 minutes. The green indicator light on the main unit (Fig. 1-B)
flashes and then stays on continuously. The main unit emits a beep.
The system is now active.
o
5.4 M
EANING OF THE INDICATOR LIGHTS
Note:
The CO sensor probe performs a reheat cycle regularly; while this is in
Lights
progress the sensor's green light flashes. The monitoring remains active
Green flashing
System switched on, initialisation phase.
System switched on, initialisation phase.
during this time.
Green fixed
System switched on, monitoring active
System switched on, monitoring active
Yellow
Fault, contact your dealer
Turning the system off:
Red
Press on / off button on the main unit and hold it down. The supply to
o
the system will be cut off automatically after the 5
5.2 A
LARM SIGNALLING
6
A
PPLICABLE CERTIFICATES
Once initialised, the system analyses the ambient air in your vehicle
continuously. If an abnormal level of CO gas, LPG or narcotics is detected,
the alarm sounds automatically.
An audible signal of approximately 85dB is emitted by the main unit. The
sensors also emit an audible signal.
Consumer service:
The red indicator lights go on.
SARL CEAL – ZI de Plaisance – 11100 Narbonne
The alarm sounds as long as the abnormal gas level persists.
Phone: +33 (0)4.68.44.16.40
To stop the alarm press the on / off button on the main unit and hold it down.
The supply to the system will be cut off automatically after the 5
Note:
Your gas detector is equipped with an anti-burglary alarm. If one of the
sensors is disconnected from the main unit while the system is switched on,
the main unit automatically goes into the alarm mode.
5.3
OPERATING CHECK
15
GAZ-PROTEC – Gas detector
Gas detector
/
OFF
switched on and initialised,
Indication
Alarm
th
beep.
th
beep.
16