Heath Zenith SH-5412 Manual De Instrucciones página 3

Ocultar thumbs Ver también para SH-5412:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fixture.
❒ Install the mounting strap as shown using two screws
that fit your junction box.
❒ The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒ Route the light control's wires through the large
gasket holes.
❒ Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mounting
White to
Strap
White
Junction box ground wire to
green ground screw on fixture.
598-1158-04
Black to
Black
Rubber
Plug
Mounting
Bolt
Gasket
Mount the Light Control
❒ Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒ Align the three slots in the decorative shell with the
lamp holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
Shell Slot
❒ Push the rubber plug firmly into place.
❒ If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
Lock Nut
Lens
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
3
To avoid water damage and
electrical shock, keep lamp
holders 30° below horizontal.
Keep lamps at least
1" (2.5 cm) from the
sensor. Do not allow
the lamps to block
the lens.
Tabla de contenido