Dual Brite™ Twin
Halogen Motion
Sensing Light
Model SL-5512
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Brite™ Timer.
• Photocell keeps the lighting off during daylight
hours.
• LED indicates motion was sensed (day or night).
This package includes:
Plastic Hanger
Rubber Plug
Cover
Sensor
Light Control
Mounting Bolt
Mounting Strap
2 Halogen Bulbs
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
© 2005 DESA Specialty Products™
6 Mounting
Screws (3 sizes)
Plate
3 Wire
Connectors
Gasket
Light Shield
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 20 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put ON-TIME switch
on the sensor bottom
to TEST and the Dual
Brite™ switch OFF.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Dual Brite™ TIMER
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light
turns on full bright for the ON-TIME (1,5 or 20 minutes)
then returns to dim mode.
Works:
Day
Night
x
/
minutes for
1
2
TEST
DUAL BRITE™
ON-TIME
Off 3 6 Dusk to
TEST 1 5 20
Dawn
AUTO
ON-TIME
TEST 1 5 20
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5 or 20 minutes
Flip light switch
off for one second
then back on*
595-5575-06
x
x
x
Tabla de contenido
loading

Resumen de contenidos para Heath Zenith Dual Brite SL-5512

  • Página 5: Luz Halógena Gemela Con Detector De Mov- Imiento Y Dual Brite

    Cuando lo prenda por primera vez espere 1 minutos hasta que el circuito se calibre. Para PRUEBA: Luz halógena gemela Ponga el interruptor de DUAL BRITE™ ON-TIME con detector de mov- tiempo (ON-TIME), al fondo del detector, en Off 3 6 Dusk to TEST 1 5 20 imiento y Dual Brite™...
  • Página 6: Instalacion

    INSTALACION ONECTE ONTROL Para una fácil instalación escoja una luz con un interruptor ❒ Apague la energía en el fusible o cortacircuitos. de pared. ❒ Quite el aparato de luz existente. Para un mejor funcionamiento, instale el aparato a casi ❒...
  • Página 7: Prueba Y Ajuste

    PRUEBA Y AJUSTE ❒ Afloje el tornillo sujetador Tornillo en la unión esférica y gire Sujetador ❒ Prenda el cortacircuitos y el interruptor de luz. despacio el detector. NOTA: El detector tiene un período de cerca de 1 Unión ❒ Camine por el área a prote- minutos de calentamiento antes de detectar Esférica gerse y dése cuenta dónde...
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se 1. El interruptor de luz está apagado. La luz se queda 1. Un faro está colocado demasiado cerca enciende. 2. El faro está flojo o fundido. prendida con- al detector o apunta a objetos cercanos 3.

Este manual también es adecuado para:

Sl-5512

Tabla de contenido