Connect the NEOSTART plug to the mains (230V 50Hz)
If a pre-charge is necessary : Place the selector on the 'Boost' position for about 5
mins
START : Switch to start without disconnecting the input from the mains
Go to the control seat of your vehicle. By ignitiating, you will activate the starter
function. If needed, reiterate the operation.
If the engine is not starting, restart a complete cycle (pre-charge, start).
Nb : if the engine is not starting after several trials, it means the battery needs a
complete charge or that there is another breakdown (mechanical, electrical, faulty
battery...)
Place the switch of the machine on OFF
Remove the clamp
Unplug the NEOSTART from the mains
PROTECTIONS
Your machine has been designed with a maximum of protections:
- The charge clamps are fully isolated
- The polarity reversal and the short circuits do not cause any danger.
A double fuse (Ref: 054547) ensures the protection.
The replacement needs to be done manually.
- The protection against the transformer overloads or starting on the charge position is ensured by
a circuit breaker on the front panel of the machine. If it trips, a manual reactivation is needed.
- Thermal protection : your machine is protected by a thermostat
(cooling about 1/4h). The green light turns off in case of overheating.
BATTERIES SULFATED OR DAMAGED
The machines NEOSTART do not detect the damaged or sulphated batteries.
a) Your battery is highly damaged if in charge, the ammeter quickly indicates very high intensities.
Your battery is definitively damaged.
b) In case of a sulfated battery : put the machine on the strongest charge mode (Boost) and regularly
watch if the ammeter indicates a charging current. As soon as the charging rises, position the
selector on the charge adapted to the battery. If nothing happens after 5 hours, your battery is
definitively damaged. This operation must be made with the battery disconnected from
the vehicle.
ADVICE AND WARNINGS
• Explosive gas, avoid flame and sparks. Whilst charging, the battery must be placed in a well
ventilated area.
•
Protect from rain and moisture
• Your charger must be plugged to an outlet linked to the earth.
• If the electricity supply cable is damaged, it must be replaced by the manufacturer, its after sales
service, or a person with the same qualifications to avoid any dangers.
• The external fuse can be replaced by the user (GYS product code 054547) and the circuit breaker
re-set by the button on the front of the machine.
• Do not use in any case to charge small batteries or non rechargeable batteries.
• The battery terminal which is not connected to the earth must be connected first. The connection
made to the chassis must be a safe distance from the Battery and Fuel pipe.