Changing The Battery Of The Remote Transmitter; Maintenance Intervals; Declaration Of Conformity; Technical Data - Cardo Magic 600 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 117
Operator closes the
Operator teaches in the travel
door slowly (soft
automatically. After CLOSED end
start) whilst door
position, moves automatically to
operator light flashes
OPEN end position. If the door
operator light flashes in intervals of
4, carry outTeaching in the door
operator (Chapter 15)
The operator
Check that the door is running
switches off during
smoothly and that the entrapment
motion.
protection device is working properly
/ Reset / Teach in the door operator
Remote transmitter is
Replace the batteries
not working, LED not
alight
Remote transmitter is
If the function message assigned to
not working
the transmission pulse is not
displayed whilst the transmitter is
actuated (see Chapter 16): Teach in
remote transmitter / Poor reception
(install optional antenna) energy-
saving lamps
The operator cannot
Check the wall keypad and control
be used via the wall
wire.
keypad (optional).
The operator cannot
Radio level too weak. There are
be used via the
interfering radio signals from other
remote transmitter
transmission sources / Carry out
(optional).
radio level check as described below
Changing the fuse
Pull out mains plug.
• Remove the operator hood, see page 164.
• Remove the faulty fuse (S1) from the fuse holder (S2) and
replace it. Make sure that the new fuse has the correct
value!
• Replace the operator hood.
Restore the mains connection.
Changing the battery of the remote
transmitter
Open the housing cover. Remove the battery, fit a new one
and replace the housing cover.
Use only leak-proof batteries. Make sure the polarity
is correct. Dispose of used batteries in an
environmentally-friendly way.

23 Maintenance intervals

Monthly
• Load switch-off (entrapment protection device)
• Emergency lock release
• Additional safety devices (if fitted)
Every 6 months
• Mounting of door operator on the ceiling and on the wall

24 Declaration of conformity

See page 167.
Declaration of incorporation see page 168.
Magic 600

25 Technical data

Mains connection
Device fuse
Power consumption at rated load
Closed current
Degree of protection
Wireless remote control
Remote transmitter range 1)
Remote transmitter batteries
Idle speed
Traction
Rated load
Stroke length
Magic 600
Magic 600 long
Total length 3)
Total length 2) 3)
Width
Width 2)
Installation height drive rail
Permissible
ambient temperatures
Storage
Lighting
Maximum number of duty cycles
per hour at rated load
Maximum number of duty cycles
without a break at rated load
Noise level at a distance of 2 m
1) The transmission range of the remote transmitter may be
reduced considerably by external interference.
2) Dimensions with turned operator head
3) plus stroke length

26 Replacement parts

See pages 162 and 163.

27 Accessories (optional)

Available from specialised dealer's:
• 4-command multi-use remote transmitter
• Wall keypad
• Key-operated control
• Keypad
• Wireless keypad
• External antenna
• Photo cell
• Extension module for opto-sensor
• Extension module for warning light
• Emergency lock release from outside or inside
• Safety rail 8.2 kohms
• Potential-free receiver, various frequencies

28 Removal, Disposal

Removing the door operator takes place in the
reverse sequence of the installation instructions
and must be carried out by qualified technicians.
Dispose of the device according to environmental
guidelines. Electrical parts must not be disposed of
as domestic waste. 2002/96/EG (WEEE)
N000924 12/2010
230 V~, 50/60 Hz
1.6 A, T (slow-blow)
140 W
< 2 W
For dry rooms
only, IP 20
Protection class 1
433.92 MHz AM
15 - 50 m
CR 2032 (3 V)
~ OPEN >210 mm/s
~ CLOSE >140 mm/s
600 N
150 N
2890 +/- 25 mm
3978 +/- 25 mm
615 +/- 25 mm
485 +/- 25 mm
285 mm
363 mm
40 mm
-20°C to 50 °C
-20°C to 80 °C
E14, max. 40 W
20
8
≤69 dB(A)
13 / 208