Conceptronic CUPS600 Manual Del Usuario página 3

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
English
1. Power LED Indicator (
 Green LED remains standstill when Utility is normal.
 Green LED flashes every 3 seconds and simultaneously buzzer
alarms continuously when Utility failure.
 Green LED flashes every 3 seconds when the UPS is in Battery
charging mode.
 Green LED remains standstill and simultaneously buzzer alarms
continuously when the UPS is in overload condition.
2. Battery LED Indicator (
 Red LED flashes every 0.5 seconds and buzzer alarms every 0.5
seconds when UPS is in battery low condition.
3. Power ON / OFF :
 To Control on/off the UPS when Utility is normal.
 To enable "DC-Start" Function when Utility fails. (To enable DC Start
properly, you are recommended to connect <80% output load with
the UPS only)
Note
:
Make sure the computer connected to the UPS is switched on
before enable the "DC-Start" function. You are not recommended
to add some other computer or peripherals after DC-Start function
is activated. pK3GrJzs
) :
) :
REAR PANEL
Tabla de contenido
loading

Este manual también es adecuado para:

Cups800

Tabla de contenido