Vimar ELVOX SL24.D Guía Rápida Para El Instalador página 9

Ocultar thumbs Ver también para ELVOX SL24.D:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
SL24.D
Immediate closing
Immediate closing not active
If the closing photocell is engaged and released
during the opening or the pause time, the control
P05
unit closes the gate, regardless of the pause
time set, 3 s after the complete opening or 3 s
after the release of the photocell (depending on
whether the release takes place during opening
or pause)
Safety input n. 63
Photocell (PH):
- with the gate stopped, does not allow the gate
to open
- during opening stops the movement and when
released proceeds with opening
- with the gate open, does not allow it to close
and when released will reload the pause time
- on closing stops the movement and when
released reopens the gate
P06
NC safety edge (BAR):
- with the gate stopped, does not allow the gate
to open
- in opening disengages, closes after the pause
time if auto close is active
- with the gate open, does not allow closing and
when released will reload the pause time
- in closing disengages and opens
8.2 KΩ balanced safety edge (8K2):
same behaviour as the NC safety edge
Output 14 type of open gate warning loght
(SCA)
Gate closed: not active
Gate not closed: active fixed
Gate closed: not active
P07
Gate in opening: slow flash
Gate not closed: active fixed
Closing gate: quick flash
Gate stopped: active fixed
Gate in opening: slow flash
Closing gate: quick flash
Safety input test
Test not active
P08
Test active on input 62
Test active on input 63
Test active on both inputs 62 and 63
Slowdown distance during closing
Gate travel in cm at slow down speed during
closing
P09
No slow down
Maximum closing slow down travel
Slowdown distance during opening
Gate travel in cm at slow down speed during
opening
P10
No slow down
Maximum opening slow down travel
Normal opening speed
Minimum speed
P11
Maximum speed
Normal closing speed
Minimum speed
P12
Maximum speed
Opening slow down speed
Minimum slow down speed
P13
Maximum slow down speed
(OFF)
Closing slow down speed
OFF
Minimum slow down speed
P14
Maximum slow down speed
Motor force (%).
Sets the value of the force given to the motor to
ON
move the gate
P15
Minimum force
Maximum force
(1)
Intensity of the stop during opening
Sudden stop
P16
Soft stop
Intensity of the stop during closing
1
Sudden stop
P17
Soft stop
Function of inputs n. 51 and 52 and radio
commands
51: step-by-step or collective command
52: pedestrian command
51: open only command
2
P18
52: close only command
51 & radio command on channel 1: open only
command
52 & radio command on channel 2: close only
command
3
Safety input n. 62
Photocell on closing (PHC)
(1)
- with the gate stopped, allows the gate to open
- during the opening does not intervene
1
- with the gate open, does not allow it to close
and when released will reload the pause time
- on closing, reopens the gate immediately
2
Photocell (PH):
P19
- with the gate stopped, does not allow the gate
to open
- during opening stops the movement and when
3
released proceeds with opening
- with the gate open, does not allow it to close
(OFF)
and when released will reload the pause time
OFF
- on closing stops the movement and when
1
released reopens the gate
2
2nd radio channel function
3
The remote control button associated with the
2nd radio channel activates output 12 as an
(75)
auxiliary radio output (RAU) for the time set in
parameter P21
P20
0
The remote control button associated with the
2nd radio channel activates the pedestrian open-
311
ing. The output 12 functions as a courtesy light
(LCO): it is activated when the gate moves and
(50)
remains active for 100 s after the gate stops
Output 12 as auxiliary radio output timer
0
(RAU)
P21
1 s (shortest time)
311
(100)
60 s (longest time)
50
Pedestrian opening position (cm)
Shortest pedestrian opening position
100
P22
(100)
Longest pedestrian opening position
50
Acceleration
Acceleration ramp until normal speed is reached
100
P24
Maximum acceleration
(30)
10
Minimum acceleration
75
EN
(30)
10
75
(3)
1
20
(1)
0
5
(1)
0
5
(0)
0
1
2
(1)
1
2
(PED)
12
PED
(1)
1
60
(150)
0
311
(1)
1
5
7
Tabla de contenido
loading

Tabla de contenido