SL24.D
Controllable actuators
Ref.
Description
ESM2.D
ACTO 600D sliding operator 24 V 600 kg, display electronic
control card
Button functions and menu browsing
Button
Description
Button to turn on the display, to access the menu and to con-
OK
firm the parameter value change. When the motor is moving,
it displays the absorption in A of the electric motor
Button to scroll up the menus and increase the parameter value
Button to scroll down the menus and decrease the parameter
value
Button to turn off the display, exit the menu and cancel the
ESC
parameter value change
51
Step-by-step command button
Preliminary checks:
After powering the unit, the name of the control board written as SL2.D,
the firmware version FX.XX and 3 flashes with the word FLSH appear in
the display, then display then goes off.
Check the diagnostic LEDs of the inputs, the LEDs 61, 62, 63 must be on,
if the limit switches are not engaged, LEDs 31 and 32 must also be on.
If one of the safety inputs (61, 62, 63) is not used, insert a bridge between
the common (99) and the unused input.
If one of the safety inputs (61, 62, 63) is open, the dot at bottom right-hand
corner of the display flashes to indicate a engaged/non-working safety that
will prevent the gate from moving. It will therefore be necessary to check
the connections and the correct functioning status of the safety devices.
Menus
The control board programming is organized in menus and submenus
that allow to access and edit the parameters and logics of the control
board. The control board features the following first level menus:
Menu
Description
LRNE
Quick gate travel calibration
LRNA
Advanced gate travel calibration
PAR
Control board parameter setting menu
RAD
Remote controls management menu
DEF
Factory reset menu
CNT
Cycle counter menu
ALM
Board alarms menu
PASS
Board protection level setting menu
Submenus
All submenus are described in the table below.
Quick gate travel calibration.
The calibration is fully self-performed and sets:
- Opening slowdown to 50 cm from the complete opening
- Slow closing at 75 cm from the complete closure
- Pedestrian opening at 150 cm
Display
Button
Phase description
msg
-
51
Wait for calibration procedure start
When button pressed: closing and search for
51
CLOS
closing limit switch
Opening travel measurement at slow down
-
OPEN
speed
-
CLOS
Closing at normal speed
-
SLO
Closing at slow down speed
-
END
End of procedure
6
Advanced gate travel calibration.
Calibration allows the installer to set:
- Opening slow down position
- Closing slow down position
- Pedestrian opening position
Display
Button
Phase description
msg
-
51
Wait for calibration procedure start
When button pressed: closing and search for clos-
51
CLOS
ing limit switch
Opening start.
51
OPEN
When button pressed: opening slow down posi-
tion setting
Continuation of opening at slow down speed up
-
SLO
to opening limit switch
Closing start.
51
CLOS
When button pressed: closing slow down posi-
tion setting
Continuation of closing at slow down speed up
-
SLO
to closing limit switch
Pedestrian opening start.
51
OPEN
When button pressed: pedestrian opening posi-
tion setting
-
CLOS
Gate closing from pedestrian opening position
-
END
End of procedure
Self-calibration:
If the gate travel parameter is changed, there is no need for the installer
to run new calibrations, however, when changing the travel parameters,
the control panel needs to learn the current curve again, thus disabling
the obstacle detection only during the self-calibration cycle. Self-calibra-
tion is appropriately highlghted on the display that shows 51, meaning
that a command is required in order for the board to self-calibrate.
The events generating self-calibration are:
- change in parameters:P09-10-11-12-13-14-15-22-24-31.
Parametri centrale
Sub
Description
menu
Auto close
P01
Auto close not active
Auto close active
Pause time
2 s (minimum time)
P02
600 s (maximum time)
Command input n. 51
Collective
During the opening the command is not active.
If P01 = ON when paused it restarts the pause
time and if the input 51 remains engaged the
control board suspends the count until the input
is disengaged (for the connection of coils or
timers).
P03
If P01 = OFF, when paused it closes back
During the closing it opens again
Step-bystep (4 steps logic)
Cycle command Opens, Stops, Closes, Stops,
Opens...
Step-bystep (2 steps logic)
Cycle command Opens, Closes, Opens...
Pre-flash
The flashing light flashes for 3 s before the gate
starts to move
P04
Pre-flash not active
3 s pre-flash active
EN
Values
(default)
(ON)
OFF
ON
(30)
2
600
(1)
1
2
3
(OFF)
OFF
ON