Franke AQCT0064 Instrucciones De Montaje página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Depending on the composition of the wall, special wall plugs may have to be used
(to be provided by the customer).
Fig. A: Water connection from above
Fig. B: Water connection from the rear
11.1 Only for water connection from the rear: Install the connection brackets (a) leak-tight.
11.2 Screw in the water volume regulators (b) leak-tight.
11.3 Align the water volume regulators so that the locking screw and operating element
are freely accessible.
11.4 For a shower head height of 2.10 m to 2.30 m, mark drill holes for installation at a
height (c) of 2.14 m to 2.34 m from the top of the finished floor.
11.5 Drill holes in accordance with these markings.
11.6 Insert the wall plugs.
11.7 Screw on the suspension rail.
11.8 Suspend the shower panel.
11.9 Mark the remaining drill holes.
11.10 Remove the shower panel.
11.11 Drill holes in accordance with these markings.
Insert the wall plugs.
The battery compartment or power supply and extension cable are not part of the
scope of delivery (see Accessories,
If you are using a wall-mounted power supply unit, it must be installed around 3 m
away from the shower.
11.12 Connect the AQUACONTACT sensor (d) to
– a battery compartment (e)
or
– a wall-mounted power supply unit (f).
If the battery charge state is low, the LED flashes in a 20 second cycle.
11.13 Remove the protective film from the shower panel.
11.14 Seal the shower panel (e.g. with Chromol, not part of the scope of delivery, see
Accessories,
Chapter
11.15 Only for water connection from the rear: Prioritise work steps 11.17 to 11.19.
11.16 Mount the shower panel on the suspension rail and screw tight.
11.17 Establish the water connections.
11.18 Open the water volume regulators using an Allen key.
a: closed
b: open
11.19 Check the water connections for leaks.
Chapter
28).
- 7 -
28).
Tabla de contenido
loading

Este manual también es adecuado para:

Aqct0065Aqct0103

Tabla de contenido