Arneg Perth 6 P Guía De Instalación Y Manejo página 69

Tabla de contenido
10 A) With the utmost delicacy, remove the upper hinge
from the upper part of the door, making sure not to exert
excess stress on the coupling between the pin and the
plastic bush;
B) Also dismantle the anti-fraying fork (1).
11 Re-mount the lower hinge unit, having now become a
left-hand unit, following phases 8-9 backwards and
insert it in place of the upperhinge.
12 Mount the upper hinge unit where the lower
hinge was previously situated.
A) Re-mount the anti-fraying fork;
B) Insert the upper hinge using a metal pipe D=16 (1);
C) Beat gently on it until the upper hinge has been fully
inserted;
D) ABSOLUTELY DO NOT BEAT DIRECTLY.
Tubo in metallo
D12-16mm
PERNO INOX
Blocco in plastica
Cornice in alluminio
del telaio porta
13 Dismantle the lower plate unit..
05060214 00 09-2021
Battere solo sulla corona
circolare in plastica come
indicato
Perth 6P - Perth 6P 1E
A
A
C
(1)
English
B
B
(1)
D