FG8MS Wireless Glassbreak Detector –
Installation Instructions
1 SELECT MOUNTING LOCATION
Refer to A (on page 1) and the following list for mounting guidelines.
• Mount the detector between the protected glass and any heavy window
coverings that may be present. When heavy window coverings are
present, the detector can be mounted on the frame of the window
2.5min
• Do NOT mount the detector:
–on posts or pillars
–in rooms with noisy equipment (air compressors, power tools, etc.),
1.8m
if this equipment is operated when the detector is armed
–where the detector's view of the glass may be obstructed unintentionally
2 CONNECT THE BATTERIES (See B on Page 1)
2a
3 SELECT PROTOCOL (See B on Page 1)
evohome=ALPHA
4 SET THE RANGE (See B on Page 1)
For best false alarm immunity, measure distance from the intended
mounting location of the detector to the farthest point of glass to be
protected. The maximum distance should be 7.6 m. Set the shortest range
available with DIP switches SENS 1 and SENS 2 that is greater than or
equal to measured distance.
5 MOUNT THE DETECTOR
Orient the microphone for the best line-of-site to the protected glass.
If ceiling mounted the end with the microphone should face the protected
glass.
Important: Not suitable for use on acoustic ceiling tiles if the rear tamper
2
will be used. Use drywall anchors if not mounting to a wall stud or ceiling
joist. If the rear tamper is used, tamper screw should screw into frame, or
1
a heavy-duty anchor, because the rear tamper requires high breakaway
force.
Reinstall the battery (if removed for rear tamper installation), then close
https://
and secure the detector front cover.
6 TEST MODES
WEB
TRANSMITTER Test Mode: This test mode shows transmitter activity.
It activates upon power-up and when the cover is opened. It remains
active for 10 minutes after the tamper switch is closed.
GLASSBREAK Test Mode: This test mode allows testing of the
glassbreak function. It is activated three ways – upon power-up,
by pressing the glassbreak test switch (see B on page 1).
For both test modes, refer to the following LED Indicators table.
1
LED INDICATORS (LEDs are only visible in test mode.)
CONDITION
Power Up
TRANSMITTER test mode
2
(10 minutes)
GLASSBREAK
Normal
test mode
Alarm
(5 minutes
)
1
Low
battery
Normal Operation (Not in
test modes)
1
5 minutes after the last sound that causes the green LED to flicker.
When registered, the FG8MS sends a low battery signal to the panel
2
when the battery voltage gets low. Replace the battery. The detector
low battery indication is approximate only.
7 TESTING GLASSBREAK WITHOUT AN FG-701 TESTER
Enter GLASSBREAK test mode. The Green LED will flash at 1Hz. Clap
hands near the detector and the Green LED will flicker, verifying the
detector is hearing room noise. To test that that the panel is detecting an
alarm, tap on the detector cover with a finger nail or screwdriver until the
Red LED turns on for 5 seconds.
30cm
2.1m - 2.7m
(2.3m)
1
3b
x2
5
2
RED LED
GREEN LED
ON 1 second
ON 1 second
1
Flashes Briefly
OFF
Once = ALPHA
Flashes Briefly
Twice = V2GY
OFF
Flashes once per
second
ON 5 seconds
and
Flashes once per
Flickers when
second
2
sound detected
OFF
OFF
3a
8 REGISTERING THE DETECTOR
1.
2
https://international.mytotalconnectcomfort.com
2.
Open and close the front cover.
3.
CR123 LITHIUM 3V
https://international.mytotalconnectcomfort.com
9 INSTALL COVER SCREW, IF REQUIRED
To secure the front cover after installation, remove the cover breakout
flash and secure the front cover with a 2.9 mm x 6.0 mm screw (not
provided.) Refer to D on page 1.
2.5min
10 SPECIFICATIONS
Protected Glass Types:
NOTE: Minimum size for all types is 28cm x 28 cm.
Glass Type*
Plate
Tempered
Laminated
Wired
Coated
2, 3
Sealed insulating
* Glass must be framed in the wall or mounted in a barrier at least 0.9m
wide.
Protected only if all plates or panes are broken.
1
Coated glass with security films up to 0.35mm (14 mils) thick (including
2
films for solar protection) may be used. Evaluated with the these products:
3M® SCOTCHSHIELD® SH14CLARL – 0.35mm (14 mils), 4 ply film; Film
Technologies International, Inc.'s GLASS-GARD GGLL 1200.
For these glass types, mounting at less than ½ the indicated range
3
setting is recommended. (Example: set SENS 1 and SENS 2 for 4.6 m
range, but mount the detector 2.3 m or less from the farthest glass to be
protected.)
2
1
https://
2b
https://
3
Nominal Thickness
Minimum
2mm
3mm
3mm
1, 3
6mm
3mm
3mm [13mm overall]
1, 3
English
3b
5
WEB
1
x2
1
2
FG8MS
https://
FG8MS
Maximum
10mm
10mm
14mm
2.5min
6mm
6mm
6mm [19mm overall]
x2
loading