Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
2.
Low water flow.
1276182-2-A
Probable Causes
Recommended Action
B. Handle is in
B. Rotate the handle to the
the closed
open position. Refer to
the "Faucet Operation"
position.
section.
C. The hot
C. Confirm the supply
and/or cold
hoses are not kinked. If
supply hose
coiled, maintain an
is kinked.
inside diameter of 3"
(76 mm).
D. The outlet
D. Confirm the solenoid
hose is
valve is located within
kinked.
7" (178 mm) to 8" (203
mm) of the faucet
centerline.
E. Refer to the "Handle
E. Handle LED
is not lit.
Switch Troubleshooting
Table."
Refer to the "Sensor
F.
Power LED
F.
on circuit
Troubleshooting Table."
board is not
lit.
G. Refer to the "Cleaning
G. One or more
screens are
the Screens" section.
clogged.
A. The supply
A. Confirm the supply
stops are
stops are fully open.
partially
closed.
B. Handle is
B. Rotate the handle to the
partially
full open position.
closed.
C. The hot
C. Confirm the supply
and/or cold
hoses are not kinked or
supply hose
twisted. If coiled,
is kinked or
maintain an inside
twisted.
diameter of 3" (76 mm).
D. The outlet
D. Confirm the solenoid
hose is
valve is located within
kinked.
7" (178 mm) to 8" (203
mm) of the faucet
centerline.
16
Kohler Co.
Tabla de contenido
loading

Este manual también es adecuado para:

K-99332