SCAN COMBIFLEX 500i/500PD
5.6
Trouble shooting
5.6.1 Common faults
Symptom
Cause
The machine won't start
There is a power failure from the power supply
The emergency stop button is depressed
Internal error
The machine is weak and
One of the three phases are missing from the
might stop when on the
ground.
There is a voltage drop at the power supply
The machine vibrates a lot
The grinding speed is to high
The tools are damaged
Table 51 Common faults
5.6.2 Error codes
Code
Description
Cause
A2001
Over current
One of the three phases is missing from the power
There is a voltage drop at the power supply
The environmental temperature is too high. When
A2002
Over voltage
The power supply has got voltage transients
A2003
Under voltage
One of the three phases is missing from the power
There is a voltage drop at the power supply
A2006
Speed reference
The potentiometer on the control panel is damaged Inspect the potentiometer
error
A2009
Over temperature
The internal temperature in the inverter is above
A5001
Internal error
F0001
Over current
F0002
Over voltage
F0003
Over temperature
The internal temperature in the inverter is above
F0004
Short circuit in
The cable to the motor has been damaged
motor
The motor has been damaged
www.scanmaskin.com
6
See access table "Table 53"
7
See access table "Table 53"
power supply
supply
the temperature is above 40°C (104°F) the inverter
will decrease its maximum output current
supply
120°C (248°F). This could be caused by faulty
ventilation in the electrical cabinet.
135°C (275°F). This could be caused by faulty
ventilation in the electrical cabinet.
Correction
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full voltage
near the machine
Release the emergency stop button.
If possible, read the alarm or fault code present at the display
inside of the electrical cabinet. Alarm codes are formatted as
"Axxxx" where "x" is the number. Fault codes are formatted
as "Fxxxx".
Contact Scanmaskin Sweden AB
Inspect the display on the inverter for any alarm code
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full voltage at
the cable end near the machine.
Make sure that the cable is not to long. If the cable should be
to long, use a cable with higher rating to a distribution box
nearer the machine.
Lower the speed
Inspect the tools
Change the tools if needed
Correction
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at
full voltage at the cable end near the machine
Make sure that the cable is not to long. If the cable
should be to long, use a cable with higher rating to
a distribution box nearer the machine
Inspect the ventilation fans
Inspect the filters to the fans
Inspect the power source
See A2001
Replace if necessary
Inspect the ventilation fans
Inspect the filters to the fans
Contact Scanmaskin Sweden AB
Contact Scanmaskin Sweden AB
Inspect the motor cable
Inspect the motor connection
Contact Scanmaskin Sweden AB
ENGLISH
A
6
O
E
E
O
O
O
O
E
E
O
O
O
O
A
7
O
O
E
E
O
O
E
S
S
O
O
See A2001
See A2002
See A2009
E
E
65