SCAN COMBIFLEX 500i/500PD
1.2
Mechanical specifications
Model
Grinding diameter
Grinding plate diameter 200 mm
Grinding plate speed
Mass
Gear barrel
Table 12
Mechanical specifications
Measurements of SC-500
Width
Height
Depth
Measurements of shipping box
Width
Height
Depth
Ambient temperature range during operation
Ambient temperature range during storage
When using water the ambient temperature must never fall below 0°C (32°F).
The water tank should be empty during storage.
1.3
Options
The SC-500 has got two options for water supply. The standard SC-500 does not come with ei-
ther of these two options.
1.3.1 Water connection
Inside the cover of the gear barrel there is a sprinkle system connected to an external water
connection. The water connection comes with its counterpart and fits a standard ½ inch hose. At
the connection that is fitted near the handle there is a tap to adjust the flow.
www.scanmaskin.com
500i
500 mm
300 – 1100 RPM
160 kg (352 lbs)
Synchronized
530 mm
20.9"
1100 mm
43.3"
1150 mm
45.3"
610 mm
24"
1410 mm
55.5"
820 mm
32.3"
500PD
19.7"
7.9"
-10°C to 50°C
-40°C to 70°C
ENGLISH
14°F to 122°F
-40°F to 158°F