7.
Position linkage bar between the two rear leg tubes (opposite the
control levers), and lower bar to rest on underside of worksurface (7a).
NOTE: Some of the linkage bars for 30" deep tables are very close in
length to linkage bars for 24" deep tables. To distinguish them from each
other, linkage bars for 30" deep tables have a 1/4" Ø identification
hole at each end (7b).
8.
To create LH clamp assembly, orient LH clamp bracket and threaded
clamp plate so that the 45° edges and holes on both parts are aligned (8a).
Insert two (2) 3/8-16 x 1/2" socket head cap screws through double holes
in LH clamp bracket and loosely fasten clamp bracket to clamp plate. Leave
about 1/4" gap between clamp bracket and clamp plate (8b). Repeat step 9
to create RH clamp assembly.
NOTE: Clamp brackets are handed. Threaded clamp plates are non-handed.
CONTROL LEVER
LINKAGE BAR
REAR LEG TUBE
7a
LH CLAMP BRACKET
8a
45
THREADED
CLAMP PLATE
LH CLAMP ASSEMBLY
8b
1/4"
26.75"
P/N 1051156003
FOR 24" x 48" TABLE
P/N 1051156009
FOR 30" x 42" TABLE
RH CLAMP BRACKET
O
EDGES ALIGN
THREADED
CLAMP PLATE
RH CLAMP ASSEMBLY
NO IDENTIFICATION HOLE
FOR 24" DEEP TABLES
1/4" Ø IDENTIFICATION HOLE
FOR 30" DEEP TABLES
26.46"
Page 3 of 24
1051162001 Rev G
7b