Safety check: Upon completion of any service or repairs to this device, ask the service technician to perform safety checks to
determine that the product is in proper operating condition.
1.3
Heat and fire hazard
Heat and Fire Hazard
Warning – risk of fire: do not place flammable or combustible materials near the device!
Barco products are designed and manufactured to meet the most stringent safety regulations.
This device radiates heat on its external surfaces during normal operation, which is both normal and safe. Exposing flammable or
combustible materials into close proximity of this device could result in the spontaneous ignition of that material, resulting in a fire.
For this reason, it is absolutely necessary to leave an "exclusion zone" around all external surfaces of the device where no flammable
or combustible materials are present. The exclusion zone must be not less than 40 cm (16") for all Barco devices. Do not cover the
device with any material while the it is in operation.
Mount the device in a well ventilated area away from sources of ignition and out of direct sun light.
In the event of fire, use sand, CO2, or dry powder fire extinguishers; never use water on an electrical fire.
1.4
Environmental Condition Check
Environment condition check
For installations in environments where the device is subject to excessive dust, then it is highly advisable and desirable to have this
dust removed prior to it reaching the device clean air supply. Devices or structures to extract or shield excessive dust well away
from the device are a prerequisite; if this is not a feasible solution then measures to relocate the device to a clean air environment
should be considered.
It is the client's responsibility to ensure at all times that the device is protected from the harmful effects of hostile airborne particles
in the environment of the device. The manufacturer reserves the right to refuse repair if a device has been subject to negligence,
abandon or improper use.
Ambient temperature conditions
Max. ambient temperature : +40°C or 104°F
Min. ambient temperature: 0°C or 32°F
Storage temperature: -10°C to +60°C (14°F to 140°F)
Humidity Conditions
Storage: 0 to 90% relative humidity, non-condensing
Operation: 0 to 85% relative humidity, non-condensing
Environment
Do not install the device in a site near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive
dust or humidity. Be aware that room heat rises to the ceiling; check that temperature near the installation site is not excessive.