Nilfisk ALTO SO 4500 Instrucciones Para El Usuario página 7

Ocultar thumbs Ver también para ALTO SO 4500:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Technical
Boiler
Wattage:
1950W
Type:
Stainless Steel
Capacity:
1.8 Litres
Continuous Fill
Steam Pressure:
4.5 Bar
Steam at source:
135°C >
Electrical
Voltage:
230V ~ single phase
Low Voltage Controls:
5V
Cord length:
10m
Capacities
Boiler:
1.8 Litres
Cold Water Tank:
5 Litres (easy fill)
Weight:
12kg
English
Trouble
Shooting
No Power
Not
Check connection
connected
to wall socket and
or faulty
socket switch. Try
power
in another wall
cable
socket
On / Off
Press On / Off
switch not
switch which will
on
illuminate when on
Fuse blown
Replace fuse with
approved 13A fuse
Unknown
Call for service
No steam
Steam Control
Turn the
turned down
control to half
fully clockwise
way
Steamer not
Wait for the
ready
"Ready to
steam" light to
illuminate
Clean water
Pour water into
tank is low
the clean water
(beeping
tank until the
sound& "refill"
beeper stops.
light is lit)
The steam
handle will
work again.
Unknown
Call for service
No steam, Just water
Steamer
Wait for the "Ready
not ready
to steam " light to
illuminate
Boiler at
Hold the steam
pressure
switch on for
and not
approximately one
heating(te
minute, ever if just
mperature
water is coming out.
less than
This will result in the
110ºC)
heater coming back
on
Unknown
Call for service
Steam Leaking from
front socket
"O"
Change and re grease
Rings
"O" Rings. To avoid
split
this happening ensure
"o" rings are grease
before every use.
"O"
Change and re grease
rings
"O" Rings. To avoid
worn
this happening ensure
"o" rings are grease
before every use.
Page 7
Tabla de contenido
loading

Tabla de contenido