Socket for additional brush wash head
15
PW 30/1 (Puzzi 10/2 Adv only)
Suction hose connection
16
Defoaming agent container (Puzzi 10/2
17
Adv only)
Cover
18
Storage compartment for detergent tabs
19
(Puzzi 10/2 Adv only)
Device carrying handle including suc-
20
tion pipe holder
Floor nozzle for carpet cleaning
21
Carpet adapter
22
Floor nozzle latch
23
Suction pipe
24
Nozzle mouthpiece
25
Union nut
26
Handle
27
Angle piece
28
Lever on the manifold
29
Spray hose
30
Suction hose
31
Spray / suction hose
32
Wastewater container, removable
33
Wastewater container carrying handle
34
Cover seal
35
Fluff filter
36
Start-up
1. Check the power cord, extension cable
and hoses for damage before each start-
up.
Installing accessories
1. Fit the suction pipe onto the floor nozzle
and hand-tighten the union nut on the
floor nozzle.
2. If necessary, slide the handle onto the
suction pipe and hand-tighten in the de-
sired position.
3. Fit the angle piece onto the suction pipe
and hand-tighten the union nut on the
angle piece.
4. Connect the suction hose to the suction
hose connection on the device. Insert
the spray hose coupling into the spray
hose connection on the device and latch
into place.
5. Connect the suction hose to the angle
piece. Connect the spray hose coupling
to the angle piece and latch into place.
Mixing the cleaning solution
DANGER
Danger from detergents
Risk of injury and damage
Observe all instructions that are included
with the detergents used.
Note
Warm water (maximum 50 °C) increases
the cleaning effect. Check the temperature
resistance of the surface to be cleaned.
Note
Use detergents sparingly to conserve the
environment.
1. Mix fresh water and detergent in a clean
container (concentration as specified for
the detergent). Dissolve the detergent in
the water.
Filling the fresh water tank
1. Pour the cleaning solution into the fresh
water tank. The filling level must not ex-
ceed the "MAX" mark.
Defoaming agent
Note
Foam is generated in the wastewater con-
tainer when cleaning previously sham-
pooed carpets. Foaming can be prevented
by adding defoaming agents.
1. Puzzi 10/1 only: Add defoaming agent
(special accessory) to the wastewater
container.
2. Puzzi 10/2 Adv only: Open the defoam-
ing agent container. Fill with defoaming
agent (special accessories).
Replacing the carpet adapter
1. Press the floor nozzle latch on one side.
2. Swing out and remove the carpet adapt-
er.
3. Insert a new carpet adapter and engage
the latch.
Working with accessories
Puzzi 10/2 Adv only:
Note
An additional power socket is provided for
connecting additional electrical devices.
English
Operation
13