Device elements

1 Electrodes
2 Suction hose
3 Air outlet, working air
4 Suction head lock
5 Air inlet, motor cooling air
6 Suction head
7 Dirt receptacle
8 Wheel
9 Steering roller bow
10 Steering roller
11 Suction support
12 Floor nozzle
13 Suction tube
14 Cable hook
15 Filter cover
16 Carrying handle
17 Push handle
18 Bender
19 Rotary switch for suction output (min-max)
20 Indicator lamp
21 Socket
22 Automatic filter dedusting
23 Main switch
24 Flat fold filter
25 Filter dedusting
26 Floor nozzle holder
27 Drain hose
28 Holder for suction pipes
29 Holder for crevice nozzle
30 Power cord
31 Nameplate
Caution
The flat pleated filter must always be in
place while vacuuming.

Anti-static system

Only for appliances with built-in socket:
Static charge is deflected by providing
earthing to the connection nozzles. This
prevents the formation of sparks and cur-
rent shocks due to attachments (option)
with electrical conductivity.
14

Start up

Dry vacuum cleaning

To vacuum fine dust, you can also use
an additional paper filter bag, a fleece
filter bag (option) or a membrane filter
(option).
Installing the paper filter bag/fleece filter bag
Illustration
 Release and remove the suction head.
 Insert the paper filter bag, fleece filter
bag (option) or membrane filter (option).
 Insert and lock the suction head.
Wet vacuum cleaning
Inserting the rubber lips
Illustration
 Remove the brush strips.
 Install the rubber lips.
Note: The structured side of the rubber lips
must point outwards.
Remove the paper filter bag/fleece filter bag
If the appliance is used to vacuum wet
dirt, the paper filter bag, the fleece filter
bag (option) or the membrane filter (op-
tion) must always be removed.
It is recommended to use a special filter
bag (wet) (see Filter systems).
Drain off dirt water
Illustration
 Drain off dirty water through the drain-
age hose.
General
If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
If the maximum liquid level is reached
the appliance will turn off automatically.
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.