5.
Application
PROTRONIC-T mains-operated, opto-electronically controlled washbasin fitting
DN 15 with aerator with integrated flow rate regulator, for connecting to pre-mixed
warm water or cold water, complete with plug-in power supply 230 V AC.
6.
Technical Specifications
Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculation flow rate:
Operating voltage:
Operating voltage:
Type of protection:
7.
Scope of Delivery
Quantity
1
1
1
1
1
8.
Dimensions
9.
Installation Example
1.0 bar
1–5 bar
10 bar
0.10 l/s
230 V AC
12 V DC
Tap IP55
Plug-in power supply IP20
Description
PROTRONIC-T pillar tap
with filter
Cleaning clip
Plug-in power supply 230 V AC/12 V DC
Fixing set
Installation and Operating Instructions
X
Extension
cable
0.6 m
without
3.6 m
3.0 m
10.6 m
10.0 m
FAR
Order No.
–
2000101456
2000101457
5