5.
Application
PROTRONIC - A3000 open non-touch, opto-electronically controlled washbasin
mixer DN 15 for connection to pre-mixed warm water or cold water supplies. With
facility for externally controlling options such as fittings settings and communication
via ECC function controller. Adjustable flow duration, down to the second.
Control functions:
– Hygiene flushing (10 seconds), 24 hours after last usage
– Safety switch-off when there is continuous reflection
Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning switch-off
6.
Technical Specifications
Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculation flow rate:
Volumetric flow:
Operating voltage:
Operating voltage Solenoid
valve cartridge:
Power consumption:
Communication:
Type of protection:
7.
Scope of Delivery
Quantity
1
1
1
1
1
1.0 bar
1–5 bar
10 bar
0.10 l/s
0.10 l/s for 3 bar flow pressure
24 V DC
12 V DC
2.5 W
Ethernet via ECC function controller
IP 68