11. Address Switches

Address switches
The Dennard 2060 can be controlled via RS 485
commands or 'up the co-ax'.
With RS 485 control each dome has to be individually
addressed using the Blue and Yellow rotary address
switches following the address chart on the previous
page.
For 'up the co-ax' control, using the built in protocol
converter, the same address switches are used to
select the protocol format for the controller being used
e.g.
BAX AC PANEL.................Blue.F Yellow.C = 252
For: Baxall a.c. controllers
DEN PANEL.......................Blue.F Yellow.D = 253
For: Dennard, BBV & DM Sprite controllers
BAX DC PANEL................Blue.F Yellow.E = 254
For: Baxall d.c. controllers
For 'up the co-ax' control using external protocol
converters like the drx 100 or DAX-DEN the address
switches should be set to Blue.0 Yellow.1 = 1.
To access the address switches remove the outer
hemisphere and inner shroud as shown in A & B.
Picture C shows the location. This operation should be
carried out in an office type environment to avoid
ingress of moist air.
Dennard 2060 Operation Manual
Fig.18
Address switches.
A
B
C
Address switches
Page. 10